Weight: |
235 kg
|
Equipment: |
Display
|
Description: |
Type of heating boiler: gas, max. heating power: 24.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
Control: |
Electronic
|
Dimensions WxHxD: |
400x700x250mm
|
Installation: |
Wall-mounted
|
Efficiency: |
90.1 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
130 mm
|
Thermal power: |
10.50 - 24.50 kW
|
LPG consumption: |
1.93 kg/h
|
Secondary heat exchanger material: |
Stainless steel
|
The combustion chamber: |
Open
|
Max. water pressure in the DHW circuit: |
6 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Max. temperature in the DHW circuit: |
62 °С
|
Max. coolant temperature: |
83 °С
|
Expansion tank volume: |
7 l
|
Burner: |
Gas
|
Gas connection: |
1/2"
|
Branch pipe for connecting the DHW circuit: |
1/2"
|
Heating circuit connection: |
3/4"
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Natural gas consumption: |
2.59 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Primary heat exchanger material: |
Copper
|
Type of heating boiler: |
Gas, convection
|
Hot water capacity at t 25°C: |
12.7 l/min
|
Hot water capacity at t 30°C: |
10.6 l/min
|
Hot water capacity at t 35°C: |
9.1 l/min
|
Hot water capacity at t 40°C: |
8 l/min
|
Hot water capacity at t 45°C: |
7.1 l/min
|