Change history for item: Gas Fondital Antea CTN 24

  1. Donny Darko 08 July 2023 05:29:26
    1. Create: Description #3395526
      Value: Type of heating boiler: gas, max. heating power: 24.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
    2. Create: Type of heating boiler #3395527
      Value: Gas, convection
    3. Create: Burner #3395528
      Value: Gas
    4. Create: Number of circuits #3395529
      Value: Double-circuit
    5. Create: Thermal power #3395530
      Value: 10.50 - 24.50 kW
    6. Create: The combustion chamber #3395531
      Value: Open
    7. Create: Efficiency #3395532
      Value: 90.1 %
    8. Create: Control #3395533
      Value: Electronic
    9. Create: Installation #3395534
      Value: Wall-mounted
    10. Create: Primary heat exchanger material #3395535
      Value: Copper
    11. Create: Secondary heat exchanger material #3395536
      Value: Stainless steel
    12. Create: Mains voltage #3395537
      Value: Single-phase
    13. Create: Peculiarities #3395538
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    14. Create: Expansion tank volume #3395539
      Value: 7 l
    15. Create: Equipment #3395540
      Value: Display
    16. Create: Fuel #3395541
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3395542
      Value: 2.59 cu. m/hour
    18. Create: LPG consumption #3395543
      Value: 1.93 kg/h
    19. Create: Nominal pressure of natural gas #3395544
      Value: 20 mbar
    20. Create: Permissible LPG pressure #3395545
      Value: 37 mbar
    21. Create: Max. coolant temperature #3395546
      Value: 83 °С
    22. Create: Max. temperature in the DHW circuit #3395547
      Value: 62 °С
    23. Create: Hot water capacity at t 25°C #3395548
      Value: 12.7 l/min
    24. Create: Hot water capacity at t 30°C #3395549
      Value: 10.6 l/min
    25. Create: Hot water capacity at t 35°C #3395550
      Value: 9.1 l/min
    26. Create: Hot water capacity at t 40°C #3395551
      Value: 8 l/min
    27. Create: Hot water capacity at t 45°C #3395552
      Value: 7.1 l/min
    28. Create: Max. water pressure in the DHW circuit #3395553
      Value: 6 bar
    29. Create: Max. water pressure in the heating circuit #3395554
      Value: 3 bar
    30. Create: Gas connection #3395555
      Value: 1/2"
    31. Create: Heating circuit connection #3395556
      Value: 3/4"
    32. Create: Branch pipe for connecting the DHW circuit #3395557
      Value: 1/2"
    33. Create: Chimney diameter #3395558
      Value: 130 mm
    34. Create: Dimensions WxHxD #3395559
      Value: 400x700x250mm
    35. Create: Weight #3395560
      Value: 235 kg
    36. Create: Image #6321087
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3627869994541322837/orig
    37. Create: Preview image #6321088
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id3627869994541322837/orig
  2. Donny Darko 30 April 2023 08:22:48
    Name: Gas Fondital Antea CTN 24; Catalog: Heating boilers