| Brand: |
Norm Measuring Systems
|
| Description: |
Type: cold water meter, connection type: flange, flange diameter: 165 mm, installation length: 200 mm, pulse output, maximum operating pressure: 16 bar, meter type: turbine
|
| Additional Information: |
Water temperature from +5 to +40 °С; vertical installation: accuracy class A, minimum flow 0.8 m³/h
|
| Connection type: |
Flange
|
| Included: |
Cold water meter
|
| Dust and moisture protection class: |
IP68
|
| Max working pressure: |
16 bar
|
| Installation length: |
200 mm
|
| Max flow: |
50 m³/hour
|
| Conditional pass: |
2"
|
| Calibration interval: |
6 years
|
| Accuracy class: |
B
|
| Counter type: |
Turbine
|
| Possibility of vertical installation: |
There is
|
| Flange diameter: |
165 mm
|
| Pulse output: |
There is
|
| Number of counters: |
1 PC.
|
| Minimum flow: |
0.4 m³/h
|
| Rated flow: |
2.5 m³/hour
|
| Type of mechanical counter: |
Dry
|