Weight: |
34 kg
|
Depth: |
324 mm
|
Equipment: |
Built-in exhaust fan, display
|
Description: |
Type of heating boiler: gas, max. thermal power: 33.20 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
|
Width: |
400
|
Height: |
727
|
Control: |
Electronic
|
Functions: |
Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection, power-on indication, flame modulation, underfloor heating connection, programmer
|
Efficiency: |
106.7 %
|
Accommodation: |
Wall
|
Power type: |
Single-phase
|
Fuel: |
Natural gas, liquefied gas
|
Combustion chamber type: |
Closed
|
Fuel consumption: |
2.57 kg/h
|
Heated area: |
300 m²
|
Minimum heat output: |
33 kW
|
LPG consumption: |
2.57 kg/h
|
Maximum coolant temperature: |
80°C
|
Expansion tank volume: |
10 l
|
Burner: |
Gas
|
Coaxial chimney diameter: |
60/100 mm
|
Gas connection: |
1/2"
|
Branch pipe for connecting the DHW circuit: |
3/4"
|
Heating circuit connection: |
3/4"
|
Separate chimney 80x80 mm: |
There is
|
Permissible LPG pressure: |
35 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Nominal natural gas pressure min.: |
17 mbar
|
Natural gas consumption: |
3.51 m³/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Stainless steel
|
The principle of operation of a gas boiler: |
Condensing
|
Type of heating boiler: |
Gas
|
Non-volatile: |
There is
|
Max. thermal power: |
33.2 kW
|
Maximum thermal load: |
33.2 kW
|
Maximum water pressure in the heating circuit: |
3 bar
|
Minimum heating medium temperature: |
20°C
|
Minimum heat load: |
33 kW
|