Equipment: |
Display
|
Description: |
Type of heating boiler: gas, max. heating power: 34.50 kW, number of circuits: double-circuit, location: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
Control: |
Electronic
|
Dimensions WxHxD: |
440x745x319 mm
|
Installation: |
Wall-mounted
|
Efficiency: |
106.4 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Thermal power: |
15 - 34.50 kW
|
LPG consumption: |
2.68 kg/hour
|
The combustion chamber: |
Closed
|
Max. water pressure in the DHW circuit: |
7 bar
|
Temperature in the DHW circuit: |
36 - 60 °С
|
Heat carrier temperature: |
35 - 82 °С
|
Thermal load: |
16.70 - 38.30 kW
|
Expansion tank volume: |
8 l
|
Burner: |
Gas
|
Coaxial chimney diameter: |
60/100 mm and 80/125 mm
|
Connection of a separate chimney diameter 80 mm: |
Yes
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Natural gas consumption: |
3.65 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Type of heating boiler: |
Gas, condensing
|
Hot water capacity at t 25°C: |
19.3 l/min
|
Hot water capacity at t 30°C: |
16 l/min
|
Hot water capacity at t 35°C: |
13.8 l/min
|