Weight: |
172 kg
|
Equipment: |
Built-in boiler, display
|
Description: |
Type of heating boiler: gas, max. heating power: 25.05 kW, number of circuits: double-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, external control connector
|
Additional Information: |
The volume of the expansion tank in the DHW system - 5 l
|
Control: |
Electronic
|
Dimensions WxHxD: |
600x1370x800mm
|
Installation: |
Floor
|
Efficiency: |
89.9 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
130 mm
|
LPG consumption: |
2.2 kg/hour
|
The volume of the built-in boiler: |
60 l
|
The combustion chamber: |
Open
|
Max. water pressure in the DHW circuit: |
6 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Max. thermal load: |
27.87 kW
|
Temperature in the DHW circuit: |
50 - 65 °С
|
Heat carrier temperature: |
40 - 90 °С
|
Expansion tank volume: |
12 l
|
Burner: |
Gas
|
Gas connection: |
1/2"
|
Branch pipe for connecting the DHW circuit: |
3/4"
|
Heating circuit connection: |
1"
|
Permissible LPG pressure: |
29 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Natural gas consumption: |
2.95 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Gas, convection
|
Max. thermal power: |
25.05 kW
|
Hot water capacity at t 30°C: |
22 l/min
|