Weight: |
31 kg
|
Equipment: |
Built-in exhaust fan, display
|
Description: |
Type of heating boiler: gas, max. heating power: 23.80 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
|
Additional Information: |
Flue gas temperature 110 C; the control board has protection against voltage drops from 165 to 300 V; power consumption 110 W; the ability to work in the mode of weather-dependent regulation; mains voltage and frequency: 230/50
|
Control: |
Electronic
|
Dimensions WxHxD: |
403x730x239 mm
|
Installation: |
Wall-mounted
|
Efficiency: |
92.9 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
100 mm
|
Thermal power: |
9.30 - 23.80 kW
|
Heated area: |
240 sq.m
|
LPG consumption: |
1.88 kg/h
|
Secondary heat exchanger material: |
Stainless steel
|
The combustion chamber: |
Closed
|
Max. water pressure in the DHW circuit: |
10 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Temperature in the DHW circuit: |
35 - 55 °С
|
Heat carrier temperature: |
35 - 85 °С
|
Thermal load: |
9.30 - 23.80 kW
|
Burner: |
Gas
|
Coaxial chimney diameter: |
60/100 mm
|
Gas connection: |
3/4"
|
Branch pipe for connecting the DHW circuit: |
1/2"
|
Heating circuit connection: |
3/4"
|
Connection of a separate chimney diameter 80 mm: |
Yes
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
30 - 20 mbar
|
Natural gas consumption: |
2.7 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Primary heat exchanger material: |
Copper
|
Type of heating boiler: |
Gas, convection
|
Hot water capacity at t 25°C: |
13.1 l/min
|
Hot water capacity at t 30°C: |
10.2 l/min
|