Weight: |
152 kg
|
Description: |
Type of heating boiler: gas, max. thermal power: 60.20 kW, number of circuits: single-circuit, location: floor, fuel: natural gas, liquefied gas, combustion chamber type: open, type of power supply: single-phase,
|
Peculiarities: |
Safety valve, connection for external control
|
Control: |
Electronic
|
Dimensions WxHxD: |
550x910x700 mm
|
Installation: |
Floor
|
Efficiency: |
93 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
150 mm
|
LPG consumption: |
4.8 kg/hour
|
The combustion chamber: |
Open
|
Max. water pressure in the heating circuit: |
3 bar
|
Max. coolant temperature: |
90 °С
|
Burner: |
Gas
|
Gas connection: |
1/2"
|
Heating circuit connection: |
1"
|
Permissible LPG pressure: |
32 mbar
|
Nominal pressure of natural gas: |
13 mbar
|
Natural gas consumption: |
6.5 cu. m/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Gas, convection
|
Max. thermal power: |
60.20 kW
|