|
Weight: |
34 kg
|
Equipment: |
Display
|
Description: |
Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
Control: |
Electronic
|
Dimensions WxHxD: |
400x700x299 mm
|
Installation: |
Wall-mounted
|
Efficiency: |
92 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Thermal power: |
8.40 - 28 kW
|
Heated area: |
280 sq.m
|
LPG consumption: |
2.4 kg/hour
|
The combustion chamber: |
Closed
|
Max. water pressure in the DHW circuit: |
10 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Heat carrier temperature: |
40 - 82 °С
|
Thermal load: |
9.30 - 31 kW
|
Burner: |
Gas
|
Gas connection: |
3/4"
|
Heating circuit connection: |
3/4"
|
Permissible LPG pressure: |
35 mbar
|
Nominal pressure of natural gas: |
10.50 - 16 mbar
|
Natural gas consumption: |
3.2 cu. m/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Copper
|
Type of heating boiler: |
Gas, convection
|