Weight: |
127 kg
|
Equipment: |
Display
|
Description: |
Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: single-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
|
Peculiarities: |
Connector for external control, thermometer
|
Additional Information: |
Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
|
Control: |
Electronic
|
Dimensions WxHxD: |
600x991x560 mm
|
Installation: |
Floor
|
Efficiency: |
92 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
130 mm
|
LPG consumption: |
2.06 kg/h
|
The combustion chamber: |
Open
|
Max. water pressure in the heating circuit: |
4 bar
|
Max. thermal load: |
26.10 kW
|
Heat carrier temperature: |
50 - 90 °C
|
Burner: |
Gas
|
Gas connection: |
1/2"
|
Heating circuit connection: |
1¼
|
Permissible LPG pressure: |
57.5 mbar
|
Nominal pressure of natural gas: |
10 - 25 mbar
|
Natural gas consumption: |
2.76 cu. m/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Gas, convection
|
Max. thermal power: |
24 kW
|