Weight: |
203 kg
|
Description: |
Type of heating boiler: combined, max. heating power: 59.70 kW, number of circuits: single-circuit, placement: floor, fuel: diesel fuel, fuel oil, natural gas, liquefied gas, combustion chamber type:
|
Peculiarities: |
Thermometer
|
Additional Information: |
2-way heat exchanger; 5 sections
|
Control: |
Mechanical
|
Dimensions WxHxD: |
450x870x685 mm
|
Installation: |
Floor
|
Efficiency: |
89 %
|
Fuel: |
Diesel fuel, fuel oil, natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
150 mm
|
Heated area: |
600 sq.m
|
LPG consumption: |
5.7 kg/hour
|
The combustion chamber: |
Open
|
Max. water pressure in the heating circuit: |
4 bar
|
Max. thermal load: |
67.10 kW
|
Heat carrier temperature: |
30 - 90 °С
|
Burner: |
Need to purchase
|
Heating circuit connection: |
1¼
|
Natural gas consumption: |
7.1 cu. m/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Combined
|
Max. thermal power: |
59.70 kW
|