Weight: |
126 kg
|
Equipment: |
Display
|
Description: |
Type of heating boiler: gas, max. heating power: 29.70 kW, number of circuits: single-circuit, placement: floor, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
|
Peculiarities: |
External control connector
|
Additional Information: |
In the heat exchanger 5 cast-iron sections; electrical power/voltage 15/230 W/V; stainless steel burner; Possibility to connect an external storage boiler for hot water
|
Control: |
Electronic
|
Dimensions WxHxD: |
350x850x680mm
|
Installation: |
Floor
|
Efficiency: |
90 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
140 mm
|
Thermal power: |
14.90 - 29.70 kW
|
LPG consumption: |
2.56 kg/h
|
The combustion chamber: |
Open
|
Max. water pressure in the heating circuit: |
3 bar
|
Heat carrier temperature: |
30 - 85 °С
|
Thermal load: |
17 - 33 kW
|
Burner: |
Gas
|
Gas connection: |
1/2"
|
Heating circuit connection: |
1¼
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
13 - 20 mbar
|
Natural gas consumption: |
3.49 cu. m/hour
|
Number of circuits: |
Single-loop
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Gas, convection
|