Weight: |
34 kg
|
Description: |
Type of heating boiler: gas, max. heating power: 17.50 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
|
Control: |
Electronic
|
Dimensions WxHxD: |
450x803x345mm
|
Installation: |
Wall-mounted
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
110 mm
|
Thermal power: |
9.30 - 17.50 kW
|
LPG consumption: |
1.51 kg/h
|
Secondary heat exchanger material: |
Stainless steel
|
The combustion chamber: |
Open
|
Max. water pressure in the DHW circuit: |
8 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Temperature in the DHW circuit: |
35 - 65 °С
|
Heat carrier temperature: |
30 - 85 °С
|
Thermal load: |
10.60 - 19.40 kW
|
Expansion tank volume: |
8 l
|
Burner: |
Gas
|
Gas connection: |
3/4"
|
Branch pipe for connecting the DHW circuit: |
1/2"
|
Heating circuit connection: |
3/4"
|
Permissible LPG pressure: |
50 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Natural gas consumption: |
2.05 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Type of heating boiler: |
Gas, convection
|
Hot water capacity at t 25°C: |
10 l/min
|
Hot water capacity at t 35°C: |
7.1 l/min
|