Weight: |
60 kg
|
Equipment: |
Built-in boiler, display, room thermostat, remote control
|
Description: |
Type of heating boiler: gas, max. thermal power: 28 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
Additional Information: |
Performance at 30% power 88%; expansion tank of the DHW circuit 3.5 l; the amount of hot water in the first 30 minutes at ΔТ = 30°C 450 l; nominal supply pressure of liquefied gas
butane 30 mbar; removable control panel
|
Control: |
Electronic
|
Dimensions WxHxD: |
600x950x466mm
|
Installation: |
Wall-mounted
|
Efficiency: |
90.3 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
Chimney diameter: |
140 mm
|
Thermal power: |
10.40 - 28 kW
|
LPG consumption: |
2.42 kg/hour
|
The volume of the built-in boiler: |
60 l
|
The combustion chamber: |
Open
|
Max. water pressure in the DHW circuit: |
6 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Temperature in the DHW circuit: |
5 - 60 °С
|
Heat carrier temperature: |
30 - 85 °С
|
Thermal load: |
11.90 - 31.10 kW
|
Expansion tank volume: |
7.5 l
|
Burner: |
Gas
|
Gas connection: |
3/4"
|
Branch pipe for connecting the DHW circuit: |
1/2"
|
Heating circuit connection: |
3/4"
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
13 - 20 mbar
|
Natural gas consumption: |
3.29 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Primary heat exchanger material: |
Copper
|
Type of heating boiler: |
Gas, convection
|
Hot water capacity at t 25°C: |
16.1 l/min
|
Hot water capacity at t 35°C: |
11.4 l/min
|