Weight: |
165 kg
|
Equipment: |
Built-in boiler, display
|
Description: |
Type of heating boiler: gas, max. heating power: 31.70 kW, number of circuits: double-circuit, location: floor, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
|
Peculiarities: |
Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
|
Additional Information: |
Control of the smoke exhaust system, heating expansion tank 10.4 l, DHW expansion tank 4 l
|
Control: |
Electronic
|
Dimensions WxHxD: |
600x1475x730mm
|
Installation: |
Floor
|
Efficiency: |
90.94 %
|
Fuel: |
Natural gas, liquefied gas
|
Mains voltage: |
Single-phase
|
LPG consumption: |
2.73 kg/h
|
The volume of the built-in boiler: |
120 l
|
The combustion chamber: |
Closed
|
Max. water pressure in the DHW circuit: |
6 bar
|
Max. water pressure in the heating circuit: |
3 bar
|
Max. temperature in the DHW circuit: |
70 °С
|
Max. thermal load: |
34.86 kW
|
Heat carrier temperature: |
33 - 82 °С
|
Expansion tank volume: |
14.4 l
|
Burner: |
Gas
|
Gas connection: |
1"
|
Branch pipe for connecting the DHW circuit: |
3/4"
|
Heating circuit connection: |
3/4"
|
Permissible LPG pressure: |
37 mbar
|
Nominal pressure of natural gas: |
20 mbar
|
Natural gas consumption: |
3.66 cu. m/hour
|
Number of circuits: |
Double-circuit
|
Primary heat exchanger material: |
Cast iron
|
Type of heating boiler: |
Gas, convection
|
Max. thermal power: |
31.70 kW
|
Hot water capacity at t 25°C: |
1049 l/min
|
Hot water capacity at t 30°C: |
750 l/min
|