Change history for item: UPS Lanches L900Pro-H RT 3 kVA

  1. Donny Darko 24 August 2023 14:07:13
    1. Create: Width #434538
      Value: 440
    2. Create: Height #434539
      Value: 88
    3. Create: Description #16646157
      Value: Output power apparent: 3000 VA, output power active: 2700 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 8, number of output power connectors total: 8, height
    4. Create: Brand #16646158
      Value: Lanches
    5. Create: Output power apparent #16646159
      Value: 3000 VA
    6. Create: Output power active #16646160
      Value: 2700 W
    7. Create: Output waveform #16646161
      Value: Sinusoid
    8. Create: Input voltage #16646162
      Value: 1-phase
    9. Create: Output voltage #16646163
      Value: 1-phase
    10. Create: Number of output power connectors total #16646164
      Value: 8
    11. Create: Number of UPS outlets #16646165
      Value: 8
    12. Create: Type of output power connectors #16646166
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16646167
      Value: 92 %
    14. Create: THD #16646168
      Value: 5 %
    15. Create: Min. input voltage #16646169
      Value: 176 V
    16. Create: Max. input voltage #16646170
      Value: 280 V
    17. Create: Min. input frequency #16646171
      Value: 40 Hz
    18. Create: Max. input frequency #16646172
      Value: 70 Hz
    19. Create: Input power factor #16646173
      Value: 0.99
    20. Create: Output voltage stability Battery mode #16646174
      Value: 1 %
    21. Create: Crest factor #16646175
      Value: 3
    22. Create: Fuse type #16646176
      Value: Auto
    23. Create: Protection functions #16646177
      Value: LAN protection, short circuit protection, overload protection, telephone line protection
    24. Create: Interfaces #16646178
      Value: RS-232, USB, slot
    25. Create: Charging time #16646179
      Value: 3 h
    26. Create: Information display #16646180
      Value: LCD screen
    27. Create: Peculiarities #16646181
      Value: Rack mountable, audible alarm, SNMP support, optional battery connection
    28. Create: Noise level #16646182
      Value: 50 dB
    29. Create: Depth #16646183
      Value: 468 mm
    30. Create: Weight #16646184
      Value: 10.04 kg
    31. Create: Height in units #16646185
      Value: 2 U
    32. Create: Additional Information #16646186
      Value: At half load input voltage range 110 - 300 V; automatic adjustment of the speed of rotation of the cooling fans depending on the load and temperature
    33. Create: Image #13103468
      URL: https://avatars.mds.yandex.net/get-mpic/4343059/img_id2283851021212977091.png/orig
    34. Create: Image #13103469
      URL: https://avatars.mds.yandex.net/get-mpic/4343059/img_id7930726784604044072.png/orig
    35. Create: Image #13103470
      URL: https://avatars.mds.yandex.net/get-mpic/3925628/img_id5904978422504106622.png/orig
    36. Create: Image #13103471
      URL: https://avatars.mds.yandex.net/get-mpic/4012481/img_id3595954083814944486.jpeg/orig
    37. Create: Preview image #13103472
      URL: https://avatars.mds.yandex.net/get-mpic/4343059/img_id2283851021212977091.png/orig
  2. Donny Darko 23 April 2023 18:34:29
    Name: UPS Lanches L900Pro-H RT 3 kVA; Catalog: Uninterruptible power supplies