Change history for item: Double conversion UPS RIELLO UPS DLP 300ER

  1. Donny Darko 24 August 2023 14:02:43
    1. Create: Width #434274
      Value: 192
    2. Create: Height #434275
      Value: 340
    3. Create: Description #16642967
      Value: Output power apparent: 3000 VA, output power active: 2100 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 7, number of output power connectors total: 7, inter
    4. Create: Brand #16642968
      Value: RIELLO UPS
    5. Create: Output power apparent #16642969
      Value: 3000 VA
    6. Create: Output power active #16642970
      Value: 2100 W
    7. Create: Output waveform #16642971
      Value: Sinusoid
    8. Create: Input voltage #16642972
      Value: 1-phase
    9. Create: Output voltage #16642973
      Value: 1-phase
    10. Create: Number of output power connectors total #16642974
      Value: 7
    11. Create: Number of UPS outlets #16642975
      Value: 7
    12. Create: Type of output power connectors #16642976
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16642977
      Value: 88 %
    14. Create: THD #16642978
      Value: 2 %
    15. Create: Min. input voltage #16642979
      Value: 180 V
    16. Create: Max. input voltage #16642980
      Value: 264 V
    17. Create: Min. input frequency #16642981
      Value: 47 Hz
    18. Create: Max. input frequency #16642982
      Value: 63 Hz
    19. Create: Input power factor #16642983
      Value: 0.97
    20. Create: Output voltage stability Battery mode #16642984
      Value: 2 %
    21. Create: Crest factor #16642985
      Value: 3
    22. Create: Protection functions #16642986
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16642987
      Value: RS-232 slot
    24. Create: Information display #16642988
      Value: LED indicators
    25. Create: Peculiarities #16642989
      Value: Automatic By-pass, audible alarm, connection of additional batteries, cold start
    26. Create: Noise level #16642990
      Value: 40 dB
    27. Create: Depth #16642991
      Value: 460 mm
    28. Create: Weight #16642992
      Value: 15 kg
    29. Create: Additional Information #16642993
      Value: Reinforced charger, operation from external batteries, support for SNMP - optional
    30. Create: Image #13102730
      URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2196693493106766540/orig
    31. Create: Preview image #13102731
      URL: https://avatars.mds.yandex.net/get-mpic/1861069/img_id2196693493106766540/orig
  2. Donny Darko 23 April 2023 18:33:55
    Name: Double conversion UPS RIELLO UPS DLP 300ER; Catalog: Uninterruptible power supplies