Change history for item: Double conversion UPS IMPULSE STAYER 11-2

  1. Donny Darko 24 August 2023 14:02:03
    1. Create: Width #434236
      Value: 191
    2. Create: Height #434237
      Value: 336
    3. Create: Description #16642349
      Value: Total output power: 2000 VA, active output power: 1800 W, power outlet type: CEE 7 euro socket, Number of UPS outlets: 4, total number of power outlets: 4, interface
    4. Create: Brand #16642350
      Value: PULSE
    5. Create: Output power apparent #16642351
      Value: 2000 VA
    6. Create: Output power active #16642352
      Value: 1800 W
    7. Create: Output waveform #16642353
      Value: Sinusoid
    8. Create: Input voltage #16642354
      Value: 1-phase
    9. Create: Output voltage #16642355
      Value: 1-phase
    10. Create: Number of output power connectors total #16642356
      Value: 4
    11. Create: Number of UPS outlets #16642357
      Value: 4
    12. Create: Type of output power connectors #16642358
      Value: CEE 7 euro socket
    13. Create: Efficiency #16642359
      Value: 85 %
    14. Create: THD #16642360
      Value: 7 %
    15. Create: Min. input voltage #16642361
      Value: 110 V
    16. Create: Max. input voltage #16642362
      Value: 290 V
    17. Create: Input power factor #16642363
      Value: 0.98
    18. Create: Output voltage stability Battery mode #16642364
      Value: 2 %
    19. Create: Crest factor #16642365
      Value: 3
    20. Create: Fuse type #16642366
      Value: Auto
    21. Create: Protection functions #16642367
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    22. Create: Interfaces #16642368
      Value: RS-232, USB, slot, dry contacts
    23. Create: Charging time #16642369
      Value: 8 h
    24. Create: Information display #16642370
      Value: LCD screen
    25. Create: Peculiarities #16642371
      Value: Automatic By-pass, battery replacement, audible alarm, SNMP support, additional battery connection, noise filtering, cold start
    26. Create: Noise level #16642372
      Value: 60 dB
    27. Create: Depth #16642373
      Value: 470 mm
    28. Create: Weight #16642374
      Value: 9 kg
    29. Create: Additional Information #16642375
      Value: Supported by the generator
    30. Create: Image #13102552
      URL: https://avatars.mds.yandex.net/get-mpic/466729/img_id4916751510987366538.jpeg/orig
    31. Create: Preview image #13102553
      URL: https://avatars.mds.yandex.net/get-mpic/466729/img_id4916751510987366538.jpeg/orig
  2. Donny Darko 23 April 2023 18:33:49
    Name: Double conversion UPS IMPULSE STAYER 11-2; Catalog: Uninterruptible power supplies