Change history for item: Tieber T-2001 double conversion UPS

  1. Donny Darko 24 August 2023 13:46:04
    1. Create: Width #433690
      Value: 191
    2. Create: Height #433691
      Value: 338
    3. Create: Description #16626960
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16626962
      Value: Tieber
    5. Create: Output power apparent #16626964
      Value: 1000 VA
    6. Create: Output power active #16626966
      Value: 800 W
    7. Create: Output waveform #16626968
      Value: Sinusoid
    8. Create: Input voltage #16626970
      Value: 1-phase
    9. Create: Output voltage #16626972
      Value: 1-phase
    10. Create: Number of output power connectors total #16626973
      Value: 2
    11. Create: Number of UPS outlets #16626975
      Value: 2
    12. Create: Type of output power connectors #16626976
      Value: CEE 7 euro socket
    13. Create: Efficiency #16626978
      Value: 84 %
    14. Create: THD #16626980
      Value: 3 %
    15. Create: Min. input voltage #16626981
      Value: 110 V
    16. Create: Max. input voltage #16626983
      Value: 300 V
    17. Create: Min. input frequency #16626984
      Value: 46 Hz
    18. Create: Max. input frequency #16626986
      Value: 64 Hz
    19. Create: Input power factor #16626988
      Value: 0.97
    20. Create: Output voltage stability Battery mode #16626990
      Value: 2 %
    21. Create: Crest factor #16626992
      Value: 3
    22. Create: Fuse type #16626994
      Value: Auto
    23. Create: Protection functions #16626996
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    24. Create: Interfaces #16626998
      Value: RS-232 slot
    25. Create: Information display #16627000
      Value: LCD screen
    26. Create: Peculiarities #16627002
      Value: Auto By-pass, Battery Swappable, Battery Hot Swap, Audible Alarm, SNMP Support, Additional Batteries, Manual By-pass, Noise Filtering, Cold Start
    27. Create: Depth #16627006
      Value: 470 mm
    28. Create: Weight #16627008
      Value: 14 kg
    29. Create: Additional Information #16627009
      Value: Designed to power boilers and the most critical load; without internal battery; the ability to connect from 4 to 6 batteries 33 A / h - 250 A / h
    30. Create: Image #13098939
      URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5354681515845425680.jpeg/orig
    31. Create: Preview image #13098940
      URL: https://avatars.mds.yandex.net/get-mpic/4119784/img_id5354681515845425680.jpeg/orig
  2. Donny Darko 23 April 2023 18:31:47
    Name: Tieber T-2001 double conversion UPS; Catalog: Uninterruptible power supplies