Change history for item: Double conversion UPS R-UPS U6000R

  1. Donny Darko 24 August 2023 13:38:00
    1. Create: Width #433317
      Value: 483
    2. Create: Height #433318
      Value: 132
    3. Create: Description #16616863
      Value: Output power apparent: 6000 VA, output power active: 5400 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 3, total number of output power connectors: 3, height
    4. Create: Brand #16616864
      Value: R-UPS
    5. Create: Output power apparent #16616865
      Value: 6000 VA
    6. Create: Output power active #16616866
      Value: 5400 W
    7. Create: Output waveform #16616867
      Value: Sinusoid
    8. Create: Input voltage #16616868
      Value: 1-phase
    9. Create: Output voltage #16616869
      Value: 1-phase
    10. Create: Number of output power connectors total #16616870
      Value: 3
    11. Create: Number of UPS outlets #16616871
      Value: 3
    12. Create: Type of output power connectors #16616872
      Value: IEC 320 C13 computer
    13. Create: Efficiency #16616873
      Value: 92 %
    14. Create: THD #16616874
      Value: 6 %
    15. Create: Min. input voltage #16616875
      Value: 160 V
    16. Create: Max. input voltage #16616876
      Value: 295 V
    17. Create: Min. input frequency #16616877
      Value: 40 Hz
    18. Create: Max. input frequency #16616878
      Value: 70 Hz
    19. Create: Input power factor #16616879
      Value: 0.99
    20. Create: Output voltage stability Battery mode #16616880
      Value: 1 %
    21. Create: Crest factor #16616881
      Value: 3
    22. Create: Protection functions #16616882
      Value: Short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16616883
      Value: RS-232 slot
    24. Create: Charging time #16616884
      Value: 8 h
    25. Create: Information display #16616885
      Value: LCD screen
    26. Create: Peculiarities #16616886
      Value: Battery swappable, rackmountable, audible alarm, noise filtering, cold start
    27. Create: Noise level #16616887
      Value: 55 dB
    28. Create: Depth #16616888
      Value: 565 mm
    29. Create: Weight #16616889
      Value: 19 kg
    30. Create: Height in units #16616890
      Value: 3 U
    31. Create: Image #13097477
      URL: https://avatars.mds.yandex.net/get-mpic/1923211/img_id8233596595467880897.jpeg/orig
    32. Create: Preview image #13097478
      URL: https://avatars.mds.yandex.net/get-mpic/1923211/img_id8233596595467880897.jpeg/orig
  2. Donny Darko 23 April 2023 18:30:44
    Name: Double conversion UPS R-UPS U6000R; Catalog: Uninterruptible power supplies