Change history for item: Double conversion UPS Legrand MegaLine 1.25 kVA 3 103 74

  1. Donny Darko 24 August 2023 13:35:07
    1. Create: Width #433179
      Value: 270
    2. Create: Height #433180
      Value: 475
    3. Create: Description #16612970
      Value: Output power apparent: 1250 VA, output power active: 875 W, operating time at full load: 52 min, interfaces: RS-232, slot
    4. Create: Brand #16612971
      Value: Legrand
    5. Create: Output power apparent #16612972
      Value: 1250 VA
    6. Create: Output power active #16612973
      Value: 875 W
    7. Create: Operating time at full load #16612974
      Value: 5.2 min
    8. Create: Output waveform #16612975
      Value: Sinusoid
    9. Create: Input voltage #16612976
      Value: 1-phase
    10. Create: Output voltage #16612977
      Value: 1-phase
    11. Create: Efficiency #16612978
      Value: 92 %
    12. Create: Min. input voltage #16612979
      Value: 184 V
    13. Create: Max. input voltage #16612980
      Value: 264 V
    14. Create: Input power factor #16612981
      Value: 0.99
    15. Create: Output voltage stability Battery mode #16612982
      Value: 1 %
    16. Create: Crest factor #16612983
      Value: 3.5
    17. Create: Protection functions #16612984
      Value: Short circuit protection, overload protection
    18. Create: Interfaces #16612985
      Value: RS-232 slot
    19. Create: Information display #16612986
      Value: LCD screen
    20. Create: Peculiarities #16612987
      Value: Automatic By-pass, audible alarm, SNMP support
    21. Create: Noise level #16612988
      Value: 40 dB
    22. Create: Depth #16612989
      Value: 570 mm
    23. Create: Weight #16612990
      Value: 23.5 kg
    24. Create: Additional Information #16612991
      Value: Expandable up to 10000VA with 3 108 35 modules
    25. Create: Image #13097040
      URL: https://avatars.mds.yandex.net/get-mpic/2017291/img_id4516761835087919099.jpeg/orig
    26. Create: Preview image #13097041
      URL: https://avatars.mds.yandex.net/get-mpic/2017291/img_id4516761835087919099.jpeg/orig
  2. Donny Darko 23 April 2023 18:30:23
    Name: Double conversion UPS Legrand MegaLine 1.25 kVA 3 103 74; Catalog: Uninterruptible power supplies