Change history for item: Double conversion UPS Legrand KEOR S 3 kVA 3 101 21

  1. Donny Darko 24 August 2023 13:32:41
    1. Create: Width #433079
      Value: 716
    2. Create: Height #433080
      Value: 275
    3. Create: Description #16609858
      Value: Output power apparent: 3000 VA, output power active: 2400 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 6, total number of power output connectors: 6, time
    4. Create: Brand #16609859
      Value: Legrand
    5. Create: Output power apparent #16609860
      Value: 3000 VA
    6. Create: Output power active #16609861
      Value: 2400 W
    7. Create: Operating time at full load #16609862
      Value: 10 min
    8. Create: Output waveform #16609863
      Value: Sinusoid
    9. Create: Input voltage #16609864
      Value: 1-phase
    10. Create: Output voltage #16609865
      Value: 1-phase
    11. Create: Number of output power connectors total #16609866
      Value: 6
    12. Create: Number of UPS outlets #16609867
      Value: 6
    13. Create: Type of output power connectors #16609868
      Value: IEC 320 C13 computer
    14. Create: Efficiency #16609869
      Value: 98 %
    15. Create: THD #16609870
      Value: 3 %
    16. Create: Min. input voltage #16609871
      Value: 160 V
    17. Create: Max. input voltage #16609872
      Value: 288 V
    18. Create: Min. input frequency #16609873
      Value: 45 Hz
    19. Create: Max. input frequency #16609874
      Value: 55 Hz
    20. Create: Input power factor #16609875
      Value: 0.99
    21. Create: Output voltage stability Battery mode #16609876
      Value: 1 %
    22. Create: Crest factor #16609877
      Value: 2.5
    23. Create: Protection functions #16609878
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    24. Create: Interfaces #16609879
      Value: RS-232, USB
    25. Create: Information display #16609880
      Value: LCD screen
    26. Create: Peculiarities #16609881
      Value: Battery replacement, audible alarm, interference filtering, cold start
    27. Create: Noise level #16609882
      Value: 50 dB
    28. Create: Depth #16609883
      Value: 776 mm
    29. Create: Weight #16609884
      Value: 5.3 kg
    30. Create: Image #13096623
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id1622302461833621530/orig
    31. Create: Preview image #13096624
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id1622302461833621530/orig
  2. Donny Darko 23 April 2023 18:30:05
    Name: Double conversion UPS Legrand KEOR S 3 kVA 3 101 21; Catalog: Uninterruptible power supplies