Change history for item: Double conversion UPS N-Power Master-Vision MV2000RM

  1. Donny Darko 24 August 2023 11:50:32
    1. Create: Width #428422
      Value: 465
    2. Create: Height #428423
      Value: 88
    3. Create: Description #16465316
      Value: Output power apparent: 2000 VA, output power active: 1400 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 6, number of output power connectors total: 6, height
    4. Create: Brand #16465317
      Value: N-Power
    5. Create: Output power apparent #16465318
      Value: 2000 VA
    6. Create: Output power active #16465319
      Value: 1400 W
    7. Create: Output waveform #16465320
      Value: Sinusoid
    8. Create: Input voltage #16465321
      Value: 1-phase
    9. Create: Output voltage #16465322
      Value: 1-phase
    10. Create: Number of output power connectors total #16465323
      Value: 6
    11. Create: Number of UPS outlets #16465324
      Value: 6
    12. Create: Type of output power connectors #16465325
      Value: IEC 320 C13 computer
    13. Create: THD #16465326
      Value: 4 %
    14. Create: Min. input voltage #16465327
      Value: 118 V
    15. Create: Max. input voltage #16465328
      Value: 300 V
    16. Create: Min. input frequency #16465329
      Value: 46 Hz
    17. Create: Max. input frequency #16465330
      Value: 54 Hz
    18. Create: Input power factor #16465331
      Value: 0.95
    19. Create: Output voltage stability Battery mode #16465332
      Value: 2 %
    20. Create: Crest factor #16465333
      Value: 3
    21. Create: Protection functions #16465334
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection
    22. Create: Interfaces #16465335
      Value: RS-232
    23. Create: Charging time #16465336
      Value: 5 h
    24. Create: Information display #16465337
      Value: LCD screen
    25. Create: Peculiarities #16465338
      Value: Auto By-pass, Rackmountable, Audible Alarm, Noise Filtering, Cold Start
    26. Create: Noise level #16465339
      Value: 50 dB
    27. Create: Depth #16465340
      Value: 440 mm
    28. Create: Weight #16465341
      Value: 34 kg
    29. Create: Height in units #16465342
      Value: 2 U
    30. Create: Additional Information #16465343
      Value: SNMP support - optional
    31. Create: Image #13071293
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id5648268491397333515/orig
    32. Create: Preview image #13071294
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id5648268491397333515/orig
  2. Donny Darko 23 April 2023 18:17:05
    Name: Double conversion UPS N-Power Master-Vision MV2000RM; Catalog: Uninterruptible power supplies