Change history for item: Double conversion UPS Inform DSPMP 1106

  1. Donny Darko 24 August 2023 11:40:58
    1. Create: Width #427936
      Value: 440
    2. Create: Height #427937
      Value: 680
    3. Create: Description #16450054
      Value: Total output power: 6000 VA, active output power: 4200 W, type of output power connectors: IEC 320 C13 computer, total number of output power connectors: 1, interfaces: RS-232, slot, dry contacts
    4. Create: Brand #16450055
      Value: Inform
    5. Create: Output power apparent #16450056
      Value: 6000 VA
    6. Create: Output power active #16450057
      Value: 4200 W
    7. Create: Output waveform #16450058
      Value: Sinusoid
    8. Create: Input voltage #16450059
      Value: 1-phase
    9. Create: Output voltage #16450060
      Value: 1-phase
    10. Create: Number of output power connectors total #16450061
      Value: 1
    11. Create: Type of output power connectors #16450062
      Value: IEC 320 C13 computer
    12. Create: Efficiency #16450063
      Value: 90 %
    13. Create: THD #16450064
      Value: 5 %
    14. Create: Min. input voltage #16450065
      Value: 160 V
    15. Create: Max. input voltage #16450066
      Value: 280 V
    16. Create: Min. input frequency #16450067
      Value: 45 Hz
    17. Create: Max. input frequency #16450068
      Value: 65 Hz
    18. Create: Input power factor #16450069
      Value: 0.99
    19. Create: Output voltage stability Battery mode #16450070
      Value: 1 %
    20. Create: Min. output frequency #16450071
      Value: 50 Hz
    21. Create: Max. output frequency #16450072
      Value: 60 Hz
    22. Create: Crest factor #16450073
      Value: 3
    23. Create: Protection functions #16450074
      Value: Short circuit protection, overload protection
    24. Create: Interfaces #16450075
      Value: RS-232, slot, dry contacts
    25. Create: Charging time #16450076
      Value: 6 h
    26. Create: Information display #16450077
      Value: LCD screen
    27. Create: Peculiarities #16450078
      Value: Battery replacement, audible alarm, SNMP support, additional battery connection, manual By-pass, cold start
    28. Create: Noise level #16450079
      Value: 50 dB
    29. Create: Depth #16450080
      Value: 176 mm
    30. Create: Weight #16450081
      Value: 5.5 kg
    31. Create: Image #13069880
      URL: https://avatars.mds.yandex.net/get-mpic/1644362/img_id8917363667988185133.png/orig
    32. Create: Image #13069881
      URL: https://avatars.mds.yandex.net/get-mpic/1526692/img_id6451257333803208189.jpeg/orig
    33. Create: Preview image #13069882
      URL: https://avatars.mds.yandex.net/get-mpic/1644362/img_id8917363667988185133.png/orig
  2. Donny Darko 23 April 2023 18:15:52
    Name: Double conversion UPS Inform DSPMP 1106; Catalog: Uninterruptible power supplies