Change history for item: Double conversion UPS CyberPower OL6KERTHD

  1. Donny Darko 24 August 2023 11:32:15
    1. Create: Width #427508
      Value: 433
    2. Create: Height #427509
      Value: 86.5
    3. Create: Description #16437584
      Value: Total output power: 6000 VA, active output power: 6000 W, type of output power connectors: CEE 7 euro socket, CEE 7 / IEC 320 C13, IEC 320 C13 computer, Number of output power connectors UPS: 7, number of output times
    4. Create: Brand #16437585
      Value: CyberPower
    5. Create: Output power apparent #16437586
      Value: 6000 VA
    6. Create: Output power active #16437587
      Value: 6000 W
    7. Create: Operating time at full load #16437588
      Value: 14 min
    8. Create: Operating time at half load #16437589
      Value: 4.9 min
    9. Create: Output waveform #16437590
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16437591
      Value: 2430 J
    11. Create: Input voltage #16437592
      Value: 1-phase
    12. Create: Output voltage #16437593
      Value: 1-phase
    13. Create: Number of output power connectors total #16437594
      Value: 7
    14. Create: Number of UPS outlets #16437595
      Value: 7
    15. Create: Type of output power connectors #16437596
      Value: CEE 7 euro socket, CEE 7 / IEC 320 C13, IEC 320 C13 computer
    16. Create: THD #16437597
      Value: 5 %
    17. Create: Min. input voltage #16437598
      Value: 200 V
    18. Create: Max. input voltage #16437599
      Value: 240 V
    19. Create: Min. input frequency #16437600
      Value: 40 Hz
    20. Create: Max. input frequency #16437601
      Value: 70 Hz
    21. Create: Input power factor #16437602
      Value: 0.99
    22. Create: Output voltage stability Battery mode #16437603
      Value: 2 %
    23. Create: Min. output frequency #16437604
      Value: 50 Hz
    24. Create: Max. output frequency #16437605
      Value: 60 Hz
    25. Create: Crest factor #16437606
      Value: 3
    26. Create: Fuse type #16437607
      Value: Auto
    27. Create: Protection functions #16437608
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    28. Create: Interfaces #16437609
      Value: RS-232, USB
    29. Create: Charging time #16437610
      Value: 4 h
    30. Create: Information display #16437611
      Value: LCD screen
    31. Create: Peculiarities #16437612
      Value: Auto By-pass, Battery swappable, Rackmountable, Hot swappable batteries, Audible alarm, Manual By-pass, Cold start
    32. Create: Depth #16437613
      Value: 720 mm
    33. Create: Weight #16437614
      Value: 42 kg
    34. Create: Height in units #16437615
      Value: 2 U
    35. Create: Additional Information #16437616
      Value: Output connector configuration: IEC C13 x 4, IEC C19 x 2, terminal block x 1
    36. Create: Image #13066258
      URL: https://avatars.mds.yandex.net/get-mpic/4076910/img_id6884167373876671650.jpeg/orig
    37. Create: Image #13066259
      URL: https://avatars.mds.yandex.net/get-mpic/1859063/img_id7524957960100155128.png/orig
    38. Create: Image #13066260
      URL: https://avatars.mds.yandex.net/get-mpic/4809583/img_id8844170538052788020.png/orig
    39. Create: Image #13066261
      URL: https://avatars.mds.yandex.net/get-mpic/5246132/img_id1535714560430556056.jpeg/orig
    40. Create: Image #13066262
      URL: https://avatars.mds.yandex.net/get-mpic/7937668/img_id2135110568440078479.jpeg/orig
    41. Create: Image #13066263
      URL: https://avatars.mds.yandex.net/get-mpic/5236584/img_id2227233085310602564.jpeg/orig
    42. Create: Image #13066264
      URL: https://avatars.mds.yandex.net/get-mpic/5219097/img_id3056953156653083683.jpeg/orig
    43. Create: Preview image #13066265
      URL: https://avatars.mds.yandex.net/get-mpic/4076910/img_id6884167373876671650.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:42
    Name: Double conversion UPS CyberPower OL6KERTHD; Catalog: Uninterruptible power supplies