Change history for item: Double conversion UPS CyberPower OL10000E

  1. Donny Darko 24 August 2023 11:30:16
    1. Create: Width #427410
      Value: 265
    2. Create: Height #427411
      Value: 600
    3. Create: Description #16434175
      Value: Total output power: 10000 VA, active output power: 9000 W, Number of UPS outlets: 10, number of total outlets: 10, full load operating time: 4 min, interfaces: RS-232, s
    4. Create: Brand #16434176
      Value: CyberPower
    5. Create: Output power apparent #16434177
      Value: 10000 VA
    6. Create: Output power active #16434178
      Value: 9000 W
    7. Create: Operating time at full load #16434179
      Value: 4 min
    8. Create: Operating time at half load #16434180
      Value: 11 min
    9. Create: Output waveform #16434181
      Value: Sinusoid
    10. Create: Max. absorbed pulse energy #16434182
      Value: 2430 J
    11. Create: Input voltage #16434183
      Value: 1-phase
    12. Create: Output voltage #16434184
      Value: 1-phase
    13. Create: Number of output power connectors total #16434185
      Value: 10
    14. Create: Number of UPS outlets #16434186
      Value: 10
    15. Create: THD #16434187
      Value: 5 %
    16. Create: Min. input voltage #16434188
      Value: 180 V
    17. Create: Max. input voltage #16434189
      Value: 280 V
    18. Create: Input power factor #16434190
      Value: 0.99
    19. Create: Output voltage stability Battery mode #16434191
      Value: 2 %
    20. Create: Crest factor #16434192
      Value: 3
    21. Create: Fuse type #16434193
      Value: Auto
    22. Create: Protection functions #16434194
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16434195
      Value: RS-232, slot, dry contacts
    24. Create: Charging time #16434196
      Value: 5 h
    25. Create: Information display #16434197
      Value: LCD screen
    26. Create: Peculiarities #16434198
      Value: Auto By-pass, Battery Swappable, Battery Hot Swap, Audible Alarm, SNMP Support, Additional Batteries, Manual By-pass, Cold Start
    27. Create: Depth #16434199
      Value: 660 mm
    28. Create: Weight #16434200
      Value: 10.5 kg
    29. Create: Additional Information #16434201
      Value: Emergency Power Off EPO port; additional input and output connectors in the form of a terminal block; output connectors IEC C13 x 8 pcs and IEC C19 x 2
    30. Create: Image #13065420
      URL: https://avatars.mds.yandex.net/get-mpic/1363071/img_id4164854735014456200.jpeg/orig
    31. Create: Image #13065421
      URL: https://avatars.mds.yandex.net/get-mpic/1336510/img_id1872049713139321419.jpeg/orig
    32. Create: Image #13065422
      URL: https://avatars.mds.yandex.net/get-mpic/1331400/img_id136399932055739012.jpeg/orig
    33. Create: Preview image #13065423
      URL: https://avatars.mds.yandex.net/get-mpic/1363071/img_id4164854735014456200.jpeg/orig
  2. Donny Darko 23 April 2023 18:14:27
    Name: Double conversion UPS CyberPower OL10000E; Catalog: Uninterruptible power supplies