Change history for item: Redundant UPS CyberPower DL650ELCD

  1. Donny Darko 24 August 2023 11:27:40
    1. Create: Width #427280
      Value: 90
    2. Create: Height #427281
      Value: 190
    3. Create: Description #16429624
      Value: Total output power: 650 VA, active output power: 360 W, type of output power connectors: CEE 7 euro socket, Number of UPS output power connectors: 3, total number of power output connectors: 3
    4. Create: Brand #16429625
      Value: CyberPower
    5. Create: Output power apparent #16429626
      Value: 650 VA
    6. Create: Output power active #16429627
      Value: 360 W
    7. Create: Output waveform #16429628
      Value: Stepwise approximation of a sinusoid
    8. Create: Switchover time to battery #16429629
      Value: 4 ms
    9. Create: Max. absorbed pulse energy #16429630
      Value: 405 J
    10. Create: Input voltage #16429631
      Value: 1-phase
    11. Create: Output voltage #16429632
      Value: 1-phase
    12. Create: Number of output power connectors total #16429633
      Value: 3
    13. Create: Number of UPS outlets #16429634
      Value: 3
    14. Create: Type of output power connectors #16429635
      Value: CEE 7 euro socket
    15. Create: Min. input voltage #16429636
      Value: 192 V
    16. Create: Max. input voltage #16429637
      Value: 253 V
    17. Create: Min. input frequency #16429638
      Value: 47 Hz
    18. Create: Max. input frequency #16429639
      Value: 63 Hz
    19. Create: Output voltage stability Battery mode #16429640
      Value: 7 %
    20. Create: Min. output frequency #16429641
      Value: 50 Hz
    21. Create: Max. output frequency #16429642
      Value: 60 Hz
    22. Create: Protection functions #16429643
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Charging time #16429644
      Value: 8 h
    24. Create: Information display #16429645
      Value: LCD screen
    25. Create: Peculiarities #16429646
      Value: Battery replacement, audible alarm, interference filtering, cold start
    26. Create: Depth #16429647
      Value: 235 mm
    27. Create: Weight #16429648
      Value: 28 kg
    28. Create: Image #13064430
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id5790560455705231237/orig
    29. Create: Image #13064431
      URL: https://avatars.mds.yandex.net/get-mpic/1750349/img_id6715864705637740799/orig
    30. Create: Image #13064432
      URL: https://avatars.mds.yandex.net/get-mpic/199079/img_id2076624570313144296/orig
    31. Create: Preview image #13064433
      URL: https://avatars.mds.yandex.net/get-mpic/1642819/img_id5790560455705231237/orig
  2. Donny Darko 23 April 2023 18:14:09
    Name: Redundant UPS CyberPower DL650ELCD; Catalog: Uninterruptible power supplies