Change history for item: Double conversion UPS Powercom MRT-3000SE

  1. Donny Darko 24 August 2023 11:16:43
    1. Create: Width #426783
      Value: 428
    2. Create: Height #426784
      Value: 54
    3. Create: Description #16412315
      Value: Output power apparent: 3000 VA, output power active: 3000 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 8, number of output power connectors total: 8, height
    4. Create: Brand #16412316
      Value: Powercom
    5. Create: Output power apparent #16412317
      Value: 3000 VA
    6. Create: Output power active #16412318
      Value: 3000 W
    7. Create: Output waveform #16412319
      Value: Sinusoid
    8. Create: Max. absorbed pulse energy #16412320
      Value: 1620 J
    9. Create: Input voltage #16412321
      Value: 1-phase
    10. Create: Output voltage #16412322
      Value: 1-phase
    11. Create: Number of output power connectors total #16412323
      Value: 8
    12. Create: Number of UPS outlets #16412324
      Value: 8
    13. Create: Type of output power connectors #16412325
      Value: IEC 320 C13 computer
    14. Create: Input power factor #16412326
      Value: 0.99
    15. Create: Output voltage stability Battery mode #16412327
      Value: 3 %
    16. Create: Min. output frequency #16412328
      Value: 50 Hz
    17. Create: Max. output frequency #16412329
      Value: 60 Hz
    18. Create: Fuse type #16412330
      Value: Auto
    19. Create: Protection functions #16412331
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    20. Create: Interfaces #16412332
      Value: RS-232, USB, slot, dry contacts
    21. Create: Charging time #16412333
      Value: 4 h
    22. Create: Information display #16412334
      Value: LCD screen
    23. Create: Peculiarities #16412335
      Value: Battery swappable, rackmountable, hot swappable batteries, audible alarm, SNMP support, additional battery connection, cold start
    24. Create: Noise level #16412336
      Value: 50 dB
    25. Create: Depth #16412337
      Value: 635 mm
    26. Create: Weight #16412338
      Value: 29 kg
    27. Create: Height in units #16412339
      Value: 2 U
    28. Create: Image #13060252
      URL: https://avatars.mds.yandex.net/get-mpic/3614670/img_id7254156443088398866.jpeg/orig
    29. Create: Image #13060253
      URL: https://avatars.mds.yandex.net/get-mpic/1544149/img_id6461172599960308064.jpeg/orig
    30. Create: Image #13060254
      URL: https://avatars.mds.yandex.net/get-mpic/7547708/img_id9120049537983845445.png/orig
    31. Create: Image #13060255
      URL: https://avatars.mds.yandex.net/get-mpic/5216590/img_id3755281258812579542.jpeg/orig
    32. Create: Image #13060256
      URL: https://avatars.mds.yandex.net/get-mpic/4721581/img_id3420245700257391023.jpeg/orig
    33. Create: Image #13060257
      URL: https://avatars.mds.yandex.net/get-mpic/5326077/img_id2410114488379104354.jpeg/orig
    34. Create: Image #13060258
      URL: https://avatars.mds.yandex.net/get-mpic/4509881/img_id4662304996116173799.jpeg/orig
    35. Create: Image #13060259
      URL: https://avatars.mds.yandex.net/get-mpic/4936426/img_id1324098874009019651.jpeg/orig
    36. Create: Preview image #13060260
      URL: https://avatars.mds.yandex.net/get-mpic/3614670/img_id7254156443088398866.jpeg/orig
  2. Donny Darko 23 April 2023 18:12:49
    Name: Double conversion UPS Powercom MRT-3000SE; Catalog: Uninterruptible power supplies