Change history for item: Double conversion UPS Powercom Vanguard VGD-6000 RM 3U+3U

  1. Donny Darko 24 August 2023 11:11:04
    1. Create: Width #426499
      Value: 428
    2. Create: Height #426500
      Value: 130
    3. Create: Description #16404194
      Value: Output power apparent: 6000 VA, output power active: 4200 W, type of output power connectors: IEC 320 C13 computer, number of output power connectors total: 10, operating time at full load: 7 min, height in
    4. Create: Brand #16404195
      Value: Powercom
    5. Create: Output power apparent #16404196
      Value: 6000 VA
    6. Create: Output power active #16404197
      Value: 4200 W
    7. Create: Operating time at full load #16404198
      Value: 7 min
    8. Create: Operating time at half load #16404199
      Value: 20 minutes
    9. Create: Output waveform #16404200
      Value: Sinusoid
    10. Create: Input voltage #16404201
      Value: 1-phase
    11. Create: Output voltage #16404202
      Value: 1-phase
    12. Create: Number of output power connectors total #16404203
      Value: 10
    13. Create: Type of output power connectors #16404204
      Value: IEC 320 C13 computer
    14. Create: Min. input voltage #16404205
      Value: 160 V
    15. Create: Max. input voltage #16404206
      Value: 276 V
    16. Create: Min. input frequency #16404207
      Value: 45 Hz
    17. Create: Max. input frequency #16404208
      Value: 65 Hz
    18. Create: Fuse type #16404209
      Value: Auto
    19. Create: Protection functions #16404210
      Value: Short circuit protection, overload protection, telephone line protection
    20. Create: Interfaces #16404211
      Value: RS-232, USB, dry contacts
    21. Create: Charging time #16404212
      Value: 4 h
    22. Create: Information display #16404213
      Value: LCD screen
    23. Create: Peculiarities #16404214
      Value: Automatic By-pass, rack-mountable, audible alarm, additional battery connection, noise filtering, cold start
    24. Create: Depth #16404215
      Value: 597 mm
    25. Create: Weight #16404216
      Value: 20 kg
    26. Create: Height in units #16404217
      Value: 3 U
    27. Create: Additional Information #16404218
      Value: Load segmentation; intelligent battery charge management technology; options: external SNMP adapter internal SNMP adapter, external battery packs; terminal block for M6 screw; battery dimensions
    28. Create: Image #13058132
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id8418259856398362505/orig
    29. Create: Preview image #13058133
      URL: https://avatars.mds.yandex.net/get-mpic/1669769/img_id8418259856398362505/orig
  2. Donny Darko 23 April 2023 18:12:08
    Name: Double conversion UPS Powercom Vanguard VGD-6000 RM 3U+3U; Catalog: Uninterruptible power supplies