Change history for item: Double Conversion UPS Powercom Vanguard VGD-700

  1. Donny Darko 24 August 2023 11:10:38
    1. Create: Width #426477
      Value: 152
    2. Create: Height #426478
      Value: 420
    3. Create: Description #16403827
      Value: Output power apparent: 1500 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, Number of UPS output power connectors: 8, total number of power output connectors: 9, inter
    4. Create: Brand #16403828
      Value: Powercom
    5. Create: Output power apparent #16403829
      Value: 700 VA
    6. Create: Output power active #16403830
      Value: 490 W
    7. Create: Operating time at full load #16403831
      Value: 7 min
    8. Create: Operating time at half load #16403832
      Value: 15 minutes
    9. Create: Output waveform #16403833
      Value: Sinusoid
    10. Create: Input voltage #16403834
      Value: 1-phase
    11. Create: Output voltage #16403835
      Value: 1-phase
    12. Create: Number of output power connectors total #16403836
      Value: 2
    13. Create: Number of UPS outlets #16403837
      Value: 2
    14. Create: Type of output power connectors #16403838
      Value: IEC 320 C13 computer
    15. Create: Min. input voltage #16403839
      Value: 160 V
    16. Create: Max. input voltage #16403840
      Value: 276 V
    17. Create: Output voltage stability Battery mode #16403841
      Value: 2 %
    18. Create: Fuse type #16403842
      Value: Auto
    19. Create: Protection functions #16403843
      Value: Short circuit protection, high voltage surge protection, overload protection, telephone line protection
    20. Create: Interfaces #16403844
      Value: RS-232, USB, dry contacts
    21. Create: Charging time #16403845
      Value: 4 h
    22. Create: Information display #16403846
      Value: LCD screen
    23. Create: Peculiarities #16403847
      Value: Automatic By-pass, audible alarm, interference filtering, cold start
    24. Create: Depth #16403848
      Value: 237 mm
    25. Create: Weight #16403849
      Value: 13.9 kg
    26. Create: Additional Information #16403850
      Value: Load segmentation; intelligent battery charge management technology; options: external SNMP adapter internal SNMP adapter external battery packs
    27. Create: Image #13058023
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id666585809582938524/orig
    28. Create: Image #13058024
      URL: https://avatars.mds.yandex.net/get-mpic/372220/img_id4886864318693528456/orig
    29. Create: Preview image #13058025
      URL: https://avatars.mds.yandex.net/get-mpic/195452/img_id666585809582938524/orig
  2. Donny Darko 23 April 2023 18:12:05