    1. Create: Width #426067
      Value: 440
    2. Create: Height #426068
      Value: 86.5
    3. Create: Description #16390983
      Value: Output power apparent: 1000 VA, output power active: 900 W, type of output power connectors: IEC 320 C13 computer, number of output power connectors total: 8, operating time at full load: 4 min, height in south
    4. Create: Brand #16390984
      Value: Powerman
    5. Create: Output power apparent #16390985
      Value: 1000 VA
    6. Create: Output power active #16390986
      Value: 900 W
    7. Create: Operating time at full load #16390987
      Value: 4 min
    8. Create: Output waveform #16390988
      Value: Sinusoid
    9. Create: Input voltage #16390989
      Value: 1-phase
    10. Create: Output voltage #16390990
      Value: 1-phase
    11. Create: Number of output power connectors total #16390991
      Value: 8
    12. Create: Type of output power connectors #16390992
      Value: IEC 320 C13 computer
    13. Create: Min. input voltage #16390993
      Value: 115 V
    14. Create: Max. input voltage #16390994
      Value: 295 V
    15. Create: Min. input frequency #16390995
      Value: 40 Hz
    16. Create: Max. input frequency #16390996
      Value: 70 Hz
    17. Create: Input power factor #16390997
      Value: 0.9
    18. Create: Output voltage stability Battery mode #16390998
      Value: 1 %
    19. Create: Min. output frequency #16390999
      Value: 50 Hz
    20. Create: Max. output frequency #16391000
      Value: 60 Hz
    21. Create: Fuse type #16391001
      Value: Auto
    22. Create: Protection functions #16391002
      Value: LAN protection, short circuit protection, high voltage surge protection, overload protection, telephone line protection
    23. Create: Interfaces #16391003
      Value: RS-232, USB
    24. Create: Charging time #16391004
      Value: 4 h
    25. Create: Information display #16391005
      Value: LCD screen
    26. Create: Peculiarities #16391006
      Value: Auto By-pass, Battery Swappable, Rack Mountable, Audible Alarm, SNMP Support, Manual By-pass, Noise Filtering
    27. Create: Noise level #16391007
      Value: 50 dB
    28. Create: Depth #16391008
      Value: 305 mm
    29. Create: Weight #16391009
      Value: 12.5 kg
    30. Create: Height in units #16391010
      Value: 2 U
    31. Create: Image #13053352
      URL: https://avatars.mds.yandex.net/get-mpic/4220209/img_id3302064039725283839.jpeg/orig
    32. Create: Image #13053353
      URL: https://avatars.mds.yandex.net/get-mpic/3927509/img_id2949110038225482986.jpeg/orig
    33. Create: Image #13053354
      URL: https://avatars.mds.yandex.net/get-mpic/3925628/img_id6433930424613624971.jpeg/orig
    34. Create: Image #13053355
      URL: https://avatars.mds.yandex.net/get-mpic/4944925/img_id1008921210935732306.jpeg/orig
    35. Create: Image #13053356
      URL: https://avatars.mds.yandex.net/get-mpic/4080439/img_id1842225478436924485.jpeg/orig
    36. Create: Image #13053357
      URL: https://avatars.mds.yandex.net/get-mpic/4732637/img_id1393251740857426841.jpeg/orig
    37. Create: Image #13053358
      URL: https://avatars.mds.yandex.net/get-mpic/1865652/img_id7488763881212905373.jpeg/orig
    38. Create: Image #13053359
      URL: https://avatars.mds.yandex.net/get-mpic/1597983/img_id3271216882426919628.jpeg/orig
    39. Create: Image #13053360
      URL: https://avatars.mds.yandex.net/get-mpic/1862701/img_id2394402733318719657.jpeg/orig
    40. Create: Image #13053361
      URL: https://avatars.mds.yandex.net/get-mpic/4341821/img_id9011396513248378081.jpeg/orig
    41. Create: Preview image #13053362
      URL: https://avatars.mds.yandex.net/get-mpic/4220209/img_id3302064039725283839.jpeg/orig
  2. Donny Darko 23 April 2023 18:10:47
    Name: Double conversion UPS Powerman ONLINE 1000 RT; Catalog: Uninterruptible power supplies