Change history for item: Double conversion UPS General Electric GT 6000 VA without batteries

  1. Donny Darko 24 August 2023 10:28:45
    1. Create: Width #424613
      Value: 660
    2. Create: Height #424614
      Value: 130
    3. Create: Description #16342384
      Value: Output power apparent: 6000 VA, output power active: 4200 W, type of output power connectors: IEC 320 C13 computer, Number of output power connectors UPS: 1, number of output power connectors total: 1, height
    4. Create: Brand #16342385
      Value: General Electric
    5. Create: Output power apparent #16342386
      Value: 6000 VA
    6. Create: Output power active #16342387
      Value: 4200 W
    7. Create: Output waveform #16342388
      Value: Sinusoid
    8. Create: Input voltage #16342389
      Value: 1-phase
    9. Create: Output voltage #16342390
      Value: 1-phase
    10. Create: Number of output power connectors total #16342391
      Value: 1
    11. Create: Number of UPS outlets #16342392
      Value: 1
    12. Create: Type of output power connectors #16342393
      Value: IEC 320 C13 computer
    13. Create: THD #16342394
      Value: 8 %
    14. Create: Min. input voltage #16342395
      Value: 84 V
    15. Create: Max. input voltage #16342396
      Value: 276 V
    16. Create: Min. input frequency #16342397
      Value: 40 Hz
    17. Create: Max. input frequency #16342398
      Value: 70 Hz
    18. Create: Input power factor #16342399
      Value: 0.97
    19. Create: Output voltage stability Battery mode #16342400
      Value: 2 %
    20. Create: Crest factor #16342401
      Value: 3
    21. Create: Fuse type #16342402
      Value: Auto
    22. Create: Protection functions #16342403
      Value: Short circuit protection, high voltage surge protection, overload protection
    23. Create: Interfaces #16342404
      Value: RS-232, USB, dry contacts
    24. Create: Charging time #16342405
      Value: 5 h
    25. Create: Peculiarities #16342406
      Value: Battery replacement, battery hot-swappable, audible alarm, additional battery connection, manual By-pass, interference filtering, cold start
    26. Create: Noise level #16342407
      Value: 55 dB
    27. Create: Depth #16342408
      Value: 410 mm
    28. Create: Weight #16342409
      Value: 24.5 kg
    29. Create: Height in units #16342410
      Value: 3 U
    30. Create: Additional Information #16342411
      Value: Simultaneously floor and rack housing, no battery cabinet, frequency conversion mode
    31. Create: Image #13042200
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4309363947575702980/orig
    32. Create: Preview image #13042201
      URL: https://avatars.mds.yandex.net/get-mpic/96484/img_id4309363947575702980/orig
  2. Donny Darko 23 April 2023 18:05:38
    Name: Double conversion UPS General Electric GT 6000 VA without batteries; Catalog: Uninterruptible power supplies