Create:
Description #11270307
Value: Type: cold water meter, connection type: thread, installation length: 300 mm, maximum operating pressure: 16 bar, meter type: vane
Create:
Brand #11270308
Value: GROEN
Create:
Counter type #11270309
Value: Vaned
Create:
Connection type #11270310
Value: Thread
Create:
Included #11270311
Value: Cold water meter
Create:
Number of counters #11270312
Value: 1 PC.
Create:
Principle of operation #11270313
Value: Mechanical multi-jet
Create:
Accuracy class #11270314
Value: C
Create:
Type of mechanical counter #11270315
Value: Dry
Create:
Installation length #11270316
Value: 300 mm
Create:
Conditional pass #11270317
Value: 2"
Create:
Rated flow #11270318
Value: 1.5 m³/hour
Create:
Max flow #11270319
Value: 30 m³/hour
Create:
Minimum flow #11270320
Value: 0.1 m³/hour
Create:
For flooded wells #11270321
Value: There is
Create:
Calibration interval #11270322
Value: 6 years
Create:
Max working pressure #11270323
Value: 16 bar
Create:
Dust and moisture protection class #11270324
Value: IP68
Create:
Additional Information #11270325
Value: Antimagnetic protection; maximum temperature - 40°С; length with connectors - 448 mm; body thread - 2 1/2″, connector thread - 2″; complete set: nut - 2 pcs., fitting - 2 pcs., gasket - 2 pcs., passport, packing