Change history for item: Ammeter Am-1m

  1. Donny Darko 06 August 2023 15:30:16
    1. Create: Height #189208
      Value: 100
    2. Create: Width #189209
      Value: 100
    3. Create: Description #7633030
      Value: Functional. purpose/application: mechanical switch, type of voltage: AC AC, type of control voltage: AC/DC AC/DC, rated switching current: 16 A, rated voltage: 230 V, installation method
    4. Create: Brand #7633031
      Value: Digitop
    5. Create: Type #7633032
      Value: Current measurement
    6. Create: Voltage type #7633033
      Value: AC change.
    7. Create: Control voltage type #7633034
      Value: AC change.
    8. Create: Connection type #7633035
      Value: Screw connection
    9. Create: Degree of protection IP #7633036
      Value: IP20
    10. Create: Mounting method #7633037
      Value: Screw
    11. Create: Rated voltage #7633038
      Value: 400 V
    12. Create: Mounting height built-in #7633039
      Value: 100 mm
    13. Create: Auxiliary quantity. normally open NO contacts #7633040
      Value: 1
    14. Create: Auxiliary quantity. normally open NO contacts leading #7633041
      Value: 1
    15. Create: Auxiliary quantity. normally closed NC contacts #7633042
      Value: 1
    16. Create: Auxiliary quantity. changeover contacts #7633043
      Value: 1
    17. Create: Modular width total number of modular distances #7633044
      Value: 1
    18. Create: Type of initiation #7633045
      Value: Digital. with one function
    19. Create: Control voltage type 1 #7633046
      Value: AC change.
    20. Create: Control voltage type 2 #7633047
      Value: AC change.
    21. Create: Pole #7633048
      Value: Definite polarity
    22. Create: Type of changeover contacts #7633049
      Value: Single contact
    23. Create: Type of control/switching #7633050
      Value: Monostable
    24. Create: Min. turn-on delay #7633051
      Value: 1 s
    25. Create: Max. turn-on delay #7633052
      Value: 1 s
    26. Create: Min. turn-off delay #7633053
      Value: 1 s
    27. Create: Max. turn-off delay #7633054
      Value: 1 s
    28. Create: Rated switching current #7633055
      Value: 63 A
    29. Create: Control voltage 2 max #7633056
      Value: 1 V
    30. Create: Control voltage 1 max #7633057
      Value: 1 V
    31. Create: Control voltage 2 min #7633058
      Value: 1 V
    32. Create: Control voltage 1 min #7633059
      Value: 1 V
    33. Create: Number of changeover contacts #7633060
      Value: 1
    34. Create: Number of normally open NO contacts #7633061
      Value: 1
    35. Create: Number of normally closed NC contacts #7633062
      Value: 1
    36. Create: Installation depth #7633063
      Value: 180 mm
    37. Create: Number of phases #7633064
      Value: 1
    38. Create: Depth #7633065
      Value: 180 mm
    39. Create: Additional Information #7633066
      Value: The size of the digital indicator is 19 mm. Remote current transformer is included with the device
    40. Create: Rated we commute. power at AC-3, 400 V #7633067
      Value: 3 kW
    41. Create: Max. luminescent power. lamps switching on in pairs #7633068
      Value: 1 VA
    42. Create: Max. luminescent power. lamps parallel compensated #7633069
      Value: 1 VA
    43. Create: Max. luminescent power. lamps #7633070
      Value: 1 VA
    44. Create: Max. power of incandescent lamps #7633071
      Value: 1 W
    45. Create: Image #9256600
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id5796445176585092281.jpeg/orig
    46. Create: Image #9256601
      URL: https://avatars.mds.yandex.net/get-mpic/5341376/img_id5011677731613696967.png/orig
    47. Create: Preview image #9256602
      URL: https://avatars.mds.yandex.net/get-mpic/4393885/img_id5796445176585092281.jpeg/orig
  2. Donny Darko 03 May 2023 11:07:58
    Name: Ammeter Am-1m; Catalog: Relay