Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 17:45:50
Create:
Width #35203
Value: 410
Create:
Height #35204
Value: 652
Create:
Description #3636339
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3636340
Value: Gas
Create:
Number of circuits #3636341
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3636342
Value: Convection
Create:
Combustion chamber type #3636343
Value: Closed
Create:
Accommodation #3636344
Value: Wall
Create:
Power type #3636345
Value: Single-phase
Create:
Control #3636346
Value: Electronic
Create:
Equipment #3636347
Value: Display
Create:
Functions #3636348
Value: Auto-diagnostics, auto-ignition, frost protection, overheating protection, switch-on indication, underfloor heating connection, programmer
Create:
Minimum heat output #3636349
Value: 46 kW
Create:
Max. thermal power #3636350
Value: 24 kW
Create:
Minimum heat load #3636351
Value: 55 kW
Create:
Maximum thermal load #3636352
Value: 26.6 kW
Create:
Efficiency #3636353
Value: 90.1 %
Create:
Heated area #3636354
Value: 240 m²
Create:
Maximum water pressure in the heating circuit #3636355
Value: 3 bar
Create:
Minimum heating medium temperature #3636356
Value: 30°C
Create:
Maximum coolant temperature #3636357
Value: 80°C
Create:
Expansion tank volume #3636358
Value: 7 l
Create:
Gas connection #3636359
Value: 3/4"
Create:
Heating circuit connection #3636360
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3636361
Value: 3/4"
Create:
Coaxial chimney diameter #3636362
Value: 60/100 mm
Create:
Separate chimney 80x80 mm #3636363
Value: There is
Create:
Burner #3636364
Value: Gas
Create:
Minimum temperature in the DHW circuit #3636365
Value: 30°C
Create:
Maximum temperature in the DHW circuit #3636366
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3636367
Value: 10 bar
Create:
Fuel #3636368
Value: Natural gas, liquefied gas
Create:
Hot water capacity at t 25°C #3636369
Value: 16.1 l/min
Create:
Nominal pressure of natural gas #3636370
Value: 20 mbar
Create:
Permissible LPG pressure #3636371
Value: 28 mbar
Create:
Natural gas consumption #3636372
Value: 1.8 m³/hour
Create:
LPG consumption #3636373
Value: 2.2 kg/h
Create:
Depth #3636374
Value: 317 mm
Create:
Weight #3636375
Value: 29 kg
Create:
Image #6365248
URL: https://avatars.mds.yandex.net/get-mpic/5302484/img_id3226926349970011697.jpeg/orig
Create:
Image #6365249
URL: https://avatars.mds.yandex.net/get-mpic/7979270/img_id6343781892191175675.jpeg/orig
Create:
Image #6365250
URL: https://avatars.mds.yandex.net/get-mpic/1521939/img_id8769935474321143131.jpeg/orig
Create:
Image #6365251
URL: https://avatars.mds.yandex.net/get-mpic/6253235/img_id8746201818224264762.jpeg/orig
Create:
Image #6365252
URL: https://avatars.mds.yandex.net/get-mpic/1864685/img_id8778665735507688134.jpeg/orig
Create:
Image #6365253
URL: https://avatars.mds.yandex.net/get-mpic/4249638/img_id4504280611123939084.jpeg/orig
Create:
Image #6365254
URL: https://avatars.mds.yandex.net/get-mpic/5139700/img_id1804398116795563394.jpeg/orig
Create:
Image #6365255
URL: https://avatars.mds.yandex.net/get-mpic/4448948/img_id2687705679301624689.jpeg/orig
Create:
Preview image #6365256
URL: https://avatars.mds.yandex.net/get-mpic/5302484/img_id3226926349970011697.jpeg/orig
Donny Darko 30 April 2023 09:24:22
Name: Wall-mounted Turbo D 24 24 kW; Catalog: Heating boilers