- Donny Darko 09 July 2023 17:45:39
-
Create:
Power type #3636312
Value: Single-phase
-
Create:
Equipment #3636313
Value: Display
-
Create:
Functions #3636314
Value: Auto-diagnostics, auto-ignition, frost protection, overheating protection, switch-on indication, underfloor heating connection, programmer
-
Create:
Minimum heat output #3636315
Value: 82 kW
-
Create:
Minimum heat load #3636316
Value: 9.5 kW
-
Create:
Maximum thermal load #3636317
Value: 35 kW
-
Create:
Expansion tank volume #3636318
Value: 7 l
-
Create:
Gas connection #3636319
Value: 3/4"
-
Create:
Heating circuit connection #3636320
Value: 3/4"
-
Create:
Branch pipe for connecting the DHW circuit #3636321
Value: 3/4"
-
Create:
Coaxial chimney diameter #3636322
Value: 60/100 mm
-
Create:
Separate chimney 80x80 mm #3636323
Value: There is
-
Create:
Burner #3636324
Value: Gas
-
Create:
Maximum water pressure in the DHW circuit #3636325
Value: 10 bar
-
Create:
Nominal pressure of natural gas #3636326
Value: 20 mbar
-
Create:
Permissible LPG pressure #3636327
Value: 28 mbar
-
Create:
LPG consumption #3636328
Value: 3 kg/h
-
Create:
Image #6365246
URL: https://avatars.mds.yandex.net/get-mpic/7726747/img_id3622368603775694369.jpeg/orig
- Donny Darko 09 July 2023 17:44:42
-
Create:
Width #35187
Value: 482
-
Create:
Height #35188
Value: 652
-
Create:
Description #3636162
Value: Type of heating boiler: gas, max. thermal power: 32.70 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, control: electronic, operating principle
-
Create:
Type of heating boiler #3636163
Value: Gas
-
Create:
Number of circuits #3636164
Value: Double-circuit
-
Create:
The principle of operation of a gas boiler #3636165
Value: Convection
-
Create:
Combustion chamber type #3636166
Value: Closed
-
Create:
Primary heat exchanger material #3636167
Value: Copper
-
Create:
Accommodation #3636168
Value: Wall
-
Create:
Control #3636169
Value: Electronic
-
Create:
Max. thermal power #3636170
Value: 32.7 kW
-
Create:
Efficiency #3636171
Value: 91 %
-
Create:
Heated area #3636172
Value: 330 m²
-
Create:
Maximum water pressure in the heating circuit #3636173
Value: 10 bar
-
Create:
Minimum heating medium temperature #3636174
Value: 30°C
-
Create:
Maximum coolant temperature #3636175
Value: 80°C
-
Create:
Minimum temperature in the DHW circuit #3636176
Value: 30°C
-
Create:
Maximum temperature in the DHW circuit #3636177
Value: 60°C
-
Create:
Fuel #3636178
Value: Natural gas
-
Create:
Hot water capacity at t 25°C #3636179
Value: 18.7 l/min
-
Create:
Natural gas consumption #3636180
Value: 3.8 m³/hour
-
Create:
Depth #3636181
Value: 328 mm
-
Create:
Weight #3636182
Value: 31.6 kg
-
Create:
Image #6365224
URL: https://avatars.mds.yandex.net/get-mpic/6277643/img_id2492916345947420634.jpeg/orig
-
Create:
Image #6365225
URL: https://avatars.mds.yandex.net/get-mpic/6214739/img_id2983796715786940594.jpeg/orig
-
Create:
Image #6365226
URL: https://avatars.mds.yandex.net/get-mpic/5068955/img_id417605427942097783.jpeg/orig
-
Create:
Image #6365227
URL: https://avatars.mds.yandex.net/get-mpic/6212300/img_id5165073717245113584.jpeg/orig
-
Create:
Image #6365228
URL: https://avatars.mds.yandex.net/get-mpic/6237625/img_id7165542911434306439.jpeg/orig
-
Create:
Image #6365229
URL: https://avatars.mds.yandex.net/get-mpic/4887838/img_id5623421236689738230.jpeg/orig
-
Create:
Preview image #6365230
URL: https://avatars.mds.yandex.net/get-mpic/6277643/img_id2492916345947420634.jpeg/orig
- Donny Darko 30 April 2023 09:24:20
Name: Wall-mounted Turbo D 32 32 kW; Catalog: Heating boilers