Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 17:43:02
Create:
Width #35163
Value: 75
Create:
Height #35164
Value: 1000
Create:
Description #3635694
Value: Type of heating boiler: gas, max. thermal power: 23 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, type of power supply: single-phase, control: electric
Create:
Type of heating boiler #3635695
Value: Gas
Create:
Number of circuits #3635696
Value: Double-circuit
Create:
The principle of operation of a liquid fuel boiler #3635697
Value: Classical
Create:
The principle of operation of a solid fuel boiler #3635698
Value: Classical
Create:
Combustion chamber type #3635699
Value: Closed
Create:
Primary heat exchanger material #3635700
Value: Copper
Create:
Accommodation #3635701
Value: Wall
Create:
Power type #3635702
Value: Single-phase/three-phase
Create:
Control #3635703
Value: Electronic
Create:
Equipment #3635704
Value: Display, remote control
Create:
Functions #3635705
Value: Self-diagnosis, auto-ignition, pump blocking protection, frost protection, overheating protection
Create:
Minimum heat output #3635706
Value: 9 kW
Create:
Max. thermal power #3635707
Value: 24 kW
Create:
Minimum heat load #3635708
Value: 20 kW
Create:
Maximum thermal load #3635709
Value: 24 kW
Create:
Efficiency #3635710
Value: 91.7 %
Create:
Heated area #3635711
Value: 200 m²
Create:
Maximum water pressure in the heating circuit #3635712
Value: 3 bar
Create:
Minimum heating medium temperature #3635713
Value: 40°C
Create:
Maximum coolant temperature #3635714
Value: 80°C
Create:
Number of power steps #3635715
Value: 3
Create:
Expansion tank volume #3635716
Value: 6 l
Create:
Gas connection #3635717
Value: 3/4"
Create:
Heating circuit connection #3635718
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3635719
Value: 1/2"
Create:
Chimney diameter #3635720
Value: 75 mm
Create:
Coaxial chimney diameter #3635721
Value: 75/100
Create:
Burner #3635722
Value: Gas
Create:
Secondary heat exchanger material #3635723
Value: Aluminum
Create:
Minimum temperature in the DHW circuit #3635724
Value: 30°C
Create:
Maximum temperature in the DHW circuit #3635725
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3635726
Value: 3 bar
Create:
Fuel #3635727
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3635728
Value: 1.79 kg/h
Create:
Hot water capacity at t 25°C #3635729
Value: 13.8 l/min
Create:
Hot water capacity at t 40°C #3635730
Value: 8.6 l/min
Create:
Depth #3635731
Value: 265 mm
Create:
Weight #3635732
Value: 28 kg
Create:
Image #6365106
URL: https://avatars.mds.yandex.net/get-mpic/5216453/img_id6354549587092548353.png/orig
Create:
Image #6365107
URL: https://avatars.mds.yandex.net/get-mpic/5234050/img_id2694887570500378179.jpeg/orig
Create:
Image #6365108
URL: https://avatars.mds.yandex.net/get-mpic/6069273/img_id1068138177593736691.jpeg/orig
Create:
Image #6365109
URL: https://avatars.mds.yandex.net/get-mpic/5210364/img_id1604062232379338546.jpeg/orig
Create:
Image #6365110
URL: https://avatars.mds.yandex.net/get-mpic/6982353/img_id2821446620457420535.jpeg/orig
Create:
Image #6365111
URL: https://avatars.mds.yandex.net/get-mpic/6175789/img_id8711472328692105316.jpeg/orig
Create:
Image #6365112
URL: https://avatars.mds.yandex.net/get-mpic/6069165/img_id8697382463666375612.jpeg/orig
Create:
Image #6365113
URL: https://avatars.mds.yandex.net/get-mpic/5210364/img_id3213805648920773632.jpeg/orig
Create:
Image #6365114
URL: https://avatars.mds.yandex.net/get-mpic/5363546/img_id2963431809977901005.jpeg/orig
Create:
Image #6365115
URL: https://avatars.mds.yandex.net/get-mpic/6259567/img_id1846080529695762007.jpeg/orig
Create:
Preview image #6365116
URL: https://avatars.mds.yandex.net/get-mpic/5216453/img_id6354549587092548353.png/orig
Donny Darko 30 April 2023 09:24:14
Name: Wall-mounted gas boiler SARMAT T-20 KW 2. K. R. Cu; Catalog: Heating boilers