Donny Darko 09 July 2023 17:24:03
Create:
Width #34956
Value: 410
Create:
Height #34957
Value: 700
Create:
Description #3633336
Value: Type of heating boiler: gas, max. thermal power: 35 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3633337
Value: Gas
Create:
Number of circuits #3633338
Value: Double-circuit
Create:
The principle of operation of a gas boiler #3633339
Value: Convection
Create:
The principle of operation of a solid fuel boiler #3633340
Value: A gas boiler
Create:
Combustion chamber type #3633341
Value: Closed
Create:
Primary heat exchanger material #3633342
Value: Copper
Create:
Accommodation #3633343
Value: Wall
Create:
Power type #3633344
Value: Single-phase
Create:
Control #3633345
Value: Electronic
Create:
Equipment #3633346
Value: Built-in exhaust fan, display, room remote control not included
Create:
Functions #3633347
Value: Self-diagnosis, auto-ignition, frost protection, overheating protection, power-on indication, electric ignition
Create:
Max. thermal power #3633348
Value: 35 kW
Create:
Maximum thermal load #3633349
Value: 35 kW
Create:
Efficiency #3633350
Value: 91 %
Create:
Heated area #3633351
Value: 350 m²
Create:
Maximum water pressure in the heating circuit #3633352
Value: 3 bar
Create:
Minimum heating medium temperature #3633353
Value: 40°C
Create:
Maximum coolant temperature #3633354
Value: 80°C
Create:
Gas connection #3633355
Value: 3/4"
Create:
Heating circuit connection #3633356
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3633357
Value: 1/2"
Create:
Chimney diameter #3633358
Value: 80 mm
Create:
Coaxial chimney diameter #3633359
Value: 60/100 mm
Create:
Separate chimney 80x80 mm #3633360
Value: There is
Create:
Burner #3633361
Value: Gas
Create:
Secondary heat exchanger material #3633362
Value: Copper
Create:
Minimum temperature in the DHW circuit #3633363
Value: 37°C
Create:
Maximum temperature in the DHW circuit #3633364
Value: 60°C
Create:
Maximum water pressure in the DHW circuit #3633365
Value: 3 bar
Create:
Fuel for automatic feeding #3633366
Value: Gas
Create:
Fuel #3633367
Value: Natural gas, liquefied gas
Create:
Fuel consumption #3633368
Value: 3.41 kg/h
Create:
Hot water capacity at t 25°C #3633369
Value: 20.1 l/min
Create:
Hot water capacity at t 40°C #3633370
Value: 12.5 l/min
Create:
Nominal natural gas pressure min. #3633371
Value: 25 mbar
Create:
Nominal pressure of natural gas #3633372
Value: 10 mbar
Create:
Permissible LPG pressure #3633373
Value: 28 mbar
Create:
Natural gas consumption #3633374
Value: 4.08 m³/h
Create:
LPG consumption #3633375
Value: 3.41 kg/h
Create:
Depth #3633376
Value: 325 mm
Create:
Weight #3633377
Value: 34 kg
Create:
Image #6364585
URL: https://avatars.mds.yandex.net/get-mpic/5232583/img_id9026898614803095550.png/orig
Create:
Image #6364586
URL: https://avatars.mds.yandex.net/get-mpic/6069165/img_id6623608604329125851.png/orig
Create:
Image #6364587
URL: https://avatars.mds.yandex.net/get-mpic/6597196/img_id5059745202326820505.png/orig
Create:
Image #6364588
URL: https://avatars.mds.yandex.net/get-mpic/4012682/img_id746474360679354607.png/orig
Create:
Image #6364589
URL: https://avatars.mds.yandex.net/get-mpic/6597196/img_id5461644996705909254.png/orig
Create:
Image #6364590
URL: https://avatars.mds.yandex.net/get-mpic/5287649/img_id6176229618912934847.jpeg/orig
Create:
Image #6364591
URL: https://avatars.mds.yandex.net/get-mpic/5284145/img_id7531170580255554800.jpeg/orig
Create:
Image #6364592
URL: https://avatars.mds.yandex.net/get-mpic/5252116/img_id6270508774559391799.png/orig
Create:
Image #6364593
URL: https://avatars.mds.yandex.net/get-mpic/1865974/img_id4152848298194952355.jpeg/orig
Create:
Image #6364594
URL: https://avatars.mds.yandex.net/get-mpic/1597983/img_id3616726552032524775.jpeg/orig
Create:
Preview image #6364595
URL: https://avatars.mds.yandex.net/get-mpic/5232583/img_id9026898614803095550.png/orig
Donny Darko 30 April 2023 09:23:31
Name: Wall-mounted double-circuit Daesung E35, 35 kW; Catalog: Heating boilers