Change history for item: Daesung A 30 29.1 kW dual circuit

  1. Donny Darko 10 July 2023 16:11:34
    1. Create: Description #3645916
      Value: Type of heating boiler: gas, max. heating power: 29.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3645917
      Value: Gas, convection
    3. Create: Burner #3645918
      Value: Gas
    4. Create: Number of circuits #3645919
      Value: Double-circuit
    5. Create: Max. thermal power #3645920
      Value: 29.10 kW
    6. Create: The combustion chamber #3645921
      Value: Closed
    7. Create: Heated area #3645922
      Value: 250 sq.m
    8. Create: Efficiency #3645923
      Value: 91 %
    9. Create: Control #3645924
      Value: Electronic
    10. Create: Installation #3645925
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3645926
      Value: Copper
    12. Create: Mains voltage #3645927
      Value: Single-phase
    13. Create: Peculiarities #3645928
      Value: Pressure gauge, external control connector, thermometer
    14. Create: Equipment #3645929
      Value: Display, remote control
    15. Create: Fuel #3645930
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3645931
      Value: 3.41 cu. m/hour
    17. Create: LPG consumption #3645932
      Value: 2.55 kg/hour
    18. Create: Nominal pressure of natural gas #3645933
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3645934
      Value: 35 mbar
    20. Create: Heat carrier temperature #3645935
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3645936
      Value: 37 - 60 °С
    22. Create: Hot water capacity at t 25°C #3645937
      Value: 16.7 l/min
    23. Create: Max. water pressure in the heating circuit #3645938
      Value: 3 bar
    24. Create: Gas connection #3645939
      Value: 3/4"
    25. Create: Heating circuit connection #3645940
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3645941
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3645942
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3645943
      Value: 460x700x220 mm
    29. Create: Weight #3645944
      Value: 26 kg
    30. Create: Additional Information #3645945
      Value: Possibility of connecting a separate chimney 75x75 mm
    31. Create: Image #6372157
      URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id3275867652974058291.jpeg/orig
    32. Create: Image #6372158
      URL: https://avatars.mds.yandex.net/get-mpic/1883514/img_id2815772014658452301.jpeg/orig
    33. Create: Preview image #6372159
      URL: https://avatars.mds.yandex.net/get-mpic/1674591/img_id3275867652974058291.jpeg/orig
  2. Donny Darko 30 April 2023 09:23:28
    Name: Daesung A 30 29.1 kW dual circuit; Catalog: Heating boilers