Change history for item: Daesung A 21 20.9 kW dual circuit

  1. Donny Darko 10 July 2023 16:11:22
    1. Create: Description #3645856
      Value: Type of heating boiler: gas, max. heating power: 20.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3645857
      Value: Gas, convection
    3. Create: Burner #3645858
      Value: Gas
    4. Create: Number of circuits #3645859
      Value: Double-circuit
    5. Create: Max. thermal power #3645860
      Value: 20.90 kW
    6. Create: The combustion chamber #3645861
      Value: Closed
    7. Create: Heated area #3645862
      Value: 180 sq.m
    8. Create: Efficiency #3645863
      Value: 91 %
    9. Create: Control #3645864
      Value: Electronic
    10. Create: Installation #3645865
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3645866
      Value: Copper
    12. Create: Mains voltage #3645867
      Value: Single-phase
    13. Create: Peculiarities #3645868
      Value: Pressure gauge, external control connector, thermometer
    14. Create: Equipment #3645869
      Value: Display, remote control
    15. Create: Fuel #3645870
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3645871
      Value: 2.45 cu. m/hour
    17. Create: LPG consumption #3645872
      Value: 1.83 kg/h
    18. Create: Nominal pressure of natural gas #3645873
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3645874
      Value: 35 mbar
    20. Create: Heat carrier temperature #3645875
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3645876
      Value: 37 - 60 °С
    22. Create: Hot water capacity at t 25°C #3645877
      Value: 12 l/min
    23. Create: Max. water pressure in the heating circuit #3645878
      Value: 3 bar
    24. Create: Gas connection #3645879
      Value: 1/2"
    25. Create: Heating circuit connection #3645880
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3645881
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3645882
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3645883
      Value: 378x616x245 mm
    29. Create: Weight #3645884
      Value: 22 kg
    30. Create: Additional Information #3645885
      Value: Possibility of connecting a separate chimney 75x75 mm
    31. Create: Image #6372149
      URL: https://avatars.mds.yandex.net/get-mpic/5221826/img_id3636458763628256685.jpeg/orig
    32. Create: Image #6372150
      URL: https://avatars.mds.yandex.net/get-mpic/1863454/img_id7153796453899102590.jpeg/orig
    33. Create: Image #6372151
      URL: https://avatars.mds.yandex.net/get-mpic/1883514/img_id2815772014658452301.jpeg/orig
    34. Create: Preview image #6372152
      URL: https://avatars.mds.yandex.net/get-mpic/5221826/img_id3636458763628256685.jpeg/orig
  2. Donny Darko 30 April 2023 09:23:27
    Name: Daesung A 21 20.9 kW dual circuit; Catalog: Heating boilers