Change history for item: Daesung A 35 34.9 kW dual circuit

  1. Donny Darko 09 July 2023 17:22:13
    1. Create: Description #3633066
      Value: Type of heating boiler: gas, max. heating power: 34.90 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3633067
      Value: Gas, convection
    3. Create: Burner #3633068
      Value: Gas
    4. Create: Number of circuits #3633069
      Value: Double-circuit
    5. Create: Max. thermal power #3633070
      Value: 34.90 kW
    6. Create: The combustion chamber #3633071
      Value: Closed
    7. Create: Heated area #3633072
      Value: 300 sq.m
    8. Create: Efficiency #3633073
      Value: 91 %
    9. Create: Control #3633074
      Value: Electronic
    10. Create: Installation #3633075
      Value: Wall-mounted
    11. Create: Primary heat exchanger material #3633076
      Value: Copper
    12. Create: Mains voltage #3633077
      Value: Single-phase
    13. Create: Peculiarities #3633078
      Value: Pressure gauge, external control connector, thermometer
    14. Create: Equipment #3633079
      Value: Display, remote control
    15. Create: Fuel #3633080
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3633081
      Value: 4.09 cu. m/hour
    17. Create: LPG consumption #3633082
      Value: 3.06 kg/hour
    18. Create: Nominal pressure of natural gas #3633083
      Value: 17 - 25 mbar
    19. Create: Permissible LPG pressure #3633084
      Value: 35 mbar
    20. Create: Heat carrier temperature #3633085
      Value: 40 - 80 °С
    21. Create: Temperature in the DHW circuit #3633086
      Value: 37 - 60 °С
    22. Create: Hot water capacity at t 25°C #3633087
      Value: 20 l/min
    23. Create: Max. water pressure in the heating circuit #3633088
      Value: 3 bar
    24. Create: Gas connection #3633089
      Value: 3/4"
    25. Create: Heating circuit connection #3633090
      Value: 3/4"
    26. Create: Branch pipe for connecting the DHW circuit #3633091
      Value: 1/2"
    27. Create: Coaxial chimney diameter #3633092
      Value: 60/100 mm
    28. Create: Dimensions WxHxD #3633093
      Value: 460x700x220 mm
    29. Create: Weight #3633094
      Value: 26 kg
    30. Create: Additional Information #3633095
      Value: Possibility of connecting a separate chimney 75x75 mm
    31. Create: Image #6364521
      URL: https://avatars.mds.yandex.net/get-mpic/5287649/img_id6270392497297770383.jpeg/orig
    32. Create: Image #6364522
      URL: https://avatars.mds.yandex.net/get-mpic/1600461/img_id7827012431033422298.jpeg/orig
    33. Create: Image #6364523
      URL: https://avatars.mds.yandex.net/get-mpic/1883514/img_id2815772014658452301.jpeg/orig
    34. Create: Preview image #6364524
      URL: https://avatars.mds.yandex.net/get-mpic/5287649/img_id6270392497297770383.jpeg/orig
  2. Donny Darko 30 April 2023 09:23:27
    Name: Daesung A 35 34.9 kW dual circuit; Catalog: Heating boilers