Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 09 July 2023 17:12:21
Create:
Description #3631931
Value: Type of heating boiler: gas, max. thermal power: 22 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: open, type of power supply: single-phase, at
Create:
Type of heating boiler #3631932
Value: Gas, convection
Create:
Burner #3631933
Value: Gas
Create:
Number of circuits #3631934
Value: Double-circuit
Create:
Thermal power #3631935
Value: 7.80 - 22 kW
Create:
Thermal load #3631936
Value: 8.90 - 24.40 kW
Create:
The combustion chamber #3631937
Value: Open
Create:
Heated area #3631938
Value: 240 sq.m
Create:
Control #3631939
Value: Electronic
Create:
Installation #3631940
Value: Wall-mounted
Create:
Power steps #3631941
Value: 7
Create:
Mains voltage #3631942
Value: Single-phase
Create:
Peculiarities #3631943
Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter, gas filter
Create:
Expansion tank volume #3631944
Value: 8 l
Create:
Equipment #3631945
Value: Display
Create:
Fuel #3631946
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3631947
Value: 2.52 cu. m/hour
Create:
LPG consumption #3631948
Value: 1.88 kg/h
Create:
Nominal pressure of natural gas #3631949
Value: 7 - 30 mbar
Create:
Permissible LPG pressure #3631950
Value: 37 mbar
Create:
Heat carrier temperature #3631951
Value: 45 - 82 °С
Create:
Temperature in the DHW circuit #3631952
Value: 40 - 60 °С
Create:
Hot water capacity at t 20°C #3631953
Value: 17.1 l/min
Create:
Hot water capacity at t 30°C #3631954
Value: 11.4 l/min
Create:
Hot water capacity at t 50°C #3631955
Value: 6.84 l/min
Create:
Max. water pressure in the DHW circuit #3631956
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3631957
Value: 3 bar
Create:
Gas connection #3631958
Value: 3/4"
Create:
Heating circuit connection #3631959
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3631960
Value: 1/2"
Create:
Chimney diameter #3631961
Value: 130 mm
Create:
Dimensions WxHxD #3631962
Value: 400x750x355mm
Create:
Weight #3631963
Value: 33 kg
Create:
Additional Information #3631964
Value: Admissible pressure of liquefied gas butane 30 mbar
Create:
Image #6363612
URL: https://avatars.mds.yandex.net/get-mpic/7724829/img_id3672016463220004046.jpeg/orig
Create:
Image #6363613
URL: https://avatars.mds.yandex.net/get-mpic/1215212/img_id4034369330299017405.jpeg/orig
Create:
Image #6363614
URL: https://avatars.mds.yandex.net/get-mpic/1539743/img_id4655154647873949018.jpeg/orig
Create:
Image #6363615
URL: https://avatars.mds.yandex.net/get-mpic/1923211/img_id1389206535963871426.jpeg/orig
Create:
Image #6363616
URL: https://avatars.mds.yandex.net/get-mpic/4011308/img_id1244833295147436471.jpeg/orig
Create:
Image #6363617
URL: https://avatars.mds.yandex.net/get-mpic/4377400/img_id7594195071765217725.png/orig
Create:
Preview image #6363618
URL: https://avatars.mds.yandex.net/get-mpic/7724829/img_id3672016463220004046.jpeg/orig
Donny Darko 30 April 2023 09:23:04
Name: Boiler gas Bosch Gaz 4000 W ZWA 24-2 K; Catalog: Heating boilers