Change history for item: Boiler gas Bosch Gaz 7000 ZWS 28-3 MFA

  1. Donny Darko 09 July 2023 17:12:03
    1. Create: Description #3631879
      Value: Type of heating boiler: gas, max. heating power: 28.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, combustion chamber type: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3631880
      Value: Gas, convection
    3. Create: Burner #3631881
      Value: Gas
    4. Create: Number of circuits #3631882
      Value: Double-circuit
    5. Create: Thermal power #3631883
      Value: 11.30 - 28.10 kW
    6. Create: Thermal load #3631884
      Value: 12.90 - 31.30 kW
    7. Create: The combustion chamber #3631885
      Value: Closed
    8. Create: Heated area #3631886
      Value: 280 sq.m
    9. Create: Efficiency #3631887
      Value: 92 %
    10. Create: Control #3631888
      Value: Electronic
    11. Create: Installation #3631889
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3631890
      Value: Copper
    13. Create: Mains voltage #3631891
      Value: Single-phase
    14. Create: Peculiarities #3631892
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    15. Create: Expansion tank volume #3631893
      Value: 8 l
    16. Create: Equipment #3631894
      Value: Display
    17. Create: Fuel #3631895
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3631896
      Value: 3.2 cu. m/hour
    19. Create: LPG consumption #3631897
      Value: 2.4 kg/hour
    20. Create: Nominal pressure of natural gas #3631898
      Value: 7 - 30 mbar
    21. Create: Permissible LPG pressure #3631899
      Value: 37 mbar
    22. Create: Heat carrier temperature #3631900
      Value: 40 - 85 °С
    23. Create: Temperature in the DHW circuit #3631901
      Value: 40 - 65 °С
    24. Create: Hot water capacity at t 20°C #3631902
      Value: 20.1 l/min
    25. Create: Hot water capacity at t 30°C #3631903
      Value: 13.4 l/min
    26. Create: Hot water capacity at t 50°C #3631904
      Value: 8.1 l/min
    27. Create: Max. water pressure in the DHW circuit #3631905
      Value: 10 bar
    28. Create: Max. water pressure in the heating circuit #3631906
      Value: 3 bar
    29. Create: Gas connection #3631907
      Value: 3/4"
    30. Create: Heating circuit connection #3631908
      Value: 3/4"
    31. Create: Branch pipe for connecting the DHW circuit #3631909
      Value: 1/2"
    32. Create: Coaxial chimney diameter #3631910
      Value: 60/100 mm
    33. Create: Dimensions WxHxD #3631911
      Value: 440x825x370 mm
    34. Create: Weight #3631912
      Value: 44.5 kg
    35. Create: Additional Information #3631913
      Value: Admissible pressure of liquefied gas - butane 30 mbar
    36. Create: Image #6363595
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
    37. Create: Image #6363596
      URL: https://avatars.mds.yandex.net/get-mpic/7519991/img_id8915079462041105076.jpeg/orig
    38. Create: Image #6363597
      URL: https://avatars.mds.yandex.net/get-mpic/5351166/img_id5582393287685689401.png/orig
    39. Create: Image #6363598
      URL: https://avatars.mds.yandex.net/get-mpic/5131700/img_id9161308403618418804.jpeg/orig
    40. Create: Image #6363599
      URL: https://avatars.mds.yandex.net/get-mpic/2017233/img_id6914939480382982451.png/orig
    41. Create: Image #6363600
      URL: https://avatars.mds.yandex.net/get-mpic/4615588/img_id2788340324821979515.jpeg/orig
    42. Create: Preview image #6363601
      URL: https://avatars.mds.yandex.net/get-mpic/4343092/img_id6294001765683636162.jpeg/orig
  2. Donny Darko 30 April 2023 09:23:03
    Name: Boiler gas Bosch Gaz 7000 ZWS 28-3 MFA; Catalog: Heating boilers