Change history for item: Wall-mounted gas boiler WBC 24-1 D

  1. Donny Darko 09 July 2023 17:11:16
    1. Create: Description #3631802
      Value: Type of heating boiler: gas, max. heating power: 24.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3631803
      Value: Gas, condensing
    3. Create: Burner #3631804
      Value: Gas
    4. Create: Number of circuits #3631805
      Value: Double-circuit
    5. Create: Thermal power #3631806
      Value: 3 - 24.10 kW
    6. Create: Thermal load #3631807
      Value: 3.10 - 24.70 kW
    7. Create: The combustion chamber #3631808
      Value: Closed
    8. Create: Heated area #3631809
      Value: 240 sq.m
    9. Create: Efficiency #3631810
      Value: 103 %
    10. Create: Control #3631811
      Value: Electronic
    11. Create: Installation #3631812
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3631813
      Value: Aluminum
    13. Create: Mains voltage #3631814
      Value: Single-phase
    14. Create: Peculiarities #3631815
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer, water filter
    15. Create: Expansion tank volume #3631816
      Value: 6 l
    16. Create: Equipment #3631817
      Value: Display
    17. Create: Fuel #3631818
      Value: Natural gas, liquefied gas
    18. Create: Natural gas consumption #3631819
      Value: 2.52 cu. m/hour
    19. Create: LPG consumption #3631820
      Value: 1.82 kg/hour
    20. Create: Nominal pressure of natural gas #3631821
      Value: 10 - 16 mbar
    21. Create: Permissible LPG pressure #3631822
      Value: 35 mbar
    22. Create: Heat carrier temperature #3631823
      Value: 30 - 82 °С
    23. Create: Max. water pressure in the heating circuit #3631824
      Value: 3 bar
    24. Create: Gas connection #3631825
      Value: 3/4"
    25. Create: Heating circuit connection #3631826
      Value: 3/4"
    26. Create: Coaxial chimney diameter #3631827
      Value: 60/100 mm and 80/125 mm
    27. Create: Connection of a separate chimney diameter 80 mm #3631828
      Value: Yes
    28. Create: Dimensions WxHxD #3631829
      Value: 400x815x300mm
    29. Create: Weight #3631830
      Value: 36 kg
    30. Create: Additional Information #3631831
      Value: Silumin heat exchanger
    31. Create: Image #6363580
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id5605520320890322735.jpeg/orig
    32. Create: Image #6363581
      URL: https://avatars.mds.yandex.net/get-mpic/1680954/img_id1363194985222107554.jpeg/orig
    33. Create: Preview image #6363582
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id5605520320890322735.jpeg/orig
  2. Donny Darko 30 April 2023 09:23:02
    Name: Wall-mounted gas boiler WBC 24-1 D; Catalog: Heating boilers