Change history for item: WARM Auros KA11112 12 kW 1-pin

  1. Donny Darko 09 July 2023 16:54:01
    1. Create: Description #3629226
      Value: Type of heating boiler: gas, max. thermal power: 12 kW, number of circuits: single-circuit, placement: wall-mounted, fuel: natural gas, type of combustion chamber: closed, control: electronic, principle of operation
    2. Create: Type of heating boiler #3629227
      Value: Gas
    3. Create: Number of circuits #3629228
      Value: Single-loop
    4. Create: The principle of operation of a gas boiler #3629229
      Value: Convection
    5. Create: Combustion chamber type #3629230
      Value: Closed
    6. Create: Accommodation #3629231
      Value: Wall
    7. Create: Control #3629232
      Value: Electronic
    8. Create: Equipment #3629233
      Value: Display
    9. Create: Functions #3629234
      Value: Pump blocking protection, frost protection
    10. Create: Minimum heat output #3629235
      Value: 9.5 kW
    11. Create: Max. thermal power #3629236
      Value: 12 kW
    12. Create: Efficiency #3629237
      Value: 94 %
    13. Create: Heated area #3629238
      Value: 120 m²
    14. Create: Maximum water pressure in the heating circuit #3629239
      Value: 3 bar
    15. Create: Maximum coolant temperature #3629240
      Value: 80°C
    16. Create: Gas connection #3629241
      Value: 3/4"
    17. Create: Heating circuit connection #3629242
      Value: 3/4"
    18. Create: Branch pipe for connecting the DHW circuit #3629243
      Value: 1/2"
    19. Create: Separate chimney 80x80 mm #3629244
      Value: There is
    20. Create: Burner #3629245
      Value: Gas
    21. Create: Minimum temperature in the DHW circuit #3629246
      Value: 30°C
    22. Create: Maximum temperature in the DHW circuit #3629247
      Value: 60°C
    23. Create: Maximum water pressure in the DHW circuit #3629248
      Value: 10 bar
    24. Create: Fuel #3629249
      Value: Natural gas
    25. Create: Hot water capacity at t 30°C #3629250
      Value: 11.5 l/min
    26. Create: Nominal pressure of natural gas #3629251
      Value: 20 mbar
    27. Create: Permissible LPG pressure #3629252
      Value: 30 mbar
    28. Create: Natural gas consumption #3629253
      Value: 2.83 m³/h
    29. Create: LPG consumption #3629254
      Value: 2.09 kg/h
    30. Create: Depth #3629255
      Value: 340 mm
    31. Create: Weight #3629256
      Value: 32 kg
    32. Create: Image #6363026
      URL: https://avatars.mds.yandex.net/get-mpic/5236802/img_id2059670598139492091.jpeg/orig
    33. Create: Image #6363027
      URL: https://avatars.mds.yandex.net/get-mpic/5219318/img_id1900197048978708884.jpeg/orig
    34. Create: Preview image #6363028
      URL: https://avatars.mds.yandex.net/get-mpic/5236802/img_id2059670598139492091.jpeg/orig
  2. Donny Darko 30 April 2023 09:22:19
    Name: WARM Auros KA11112 12 kW 1-pin; Catalog: Heating boilers