Root
Construction and repair
Heating and ventilation
Heating boilers
Donny Darko 10 July 2023 15:05:13
Create:
Built-in circulation pump #3642642
Value: There is
Create:
Built-in expansion tank #3642643
Value: There is
Create:
Functions #3642644
Value: Frost protection, pressure gauge
Create:
Peculiarities #3642645
Value: External control connection
Create:
Protection #3642646
Value: Gas control, safety valve, air vent
Donny Darko 09 July 2023 16:17:47
Create:
Description #3624339
Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
Create:
Type of heating boiler #3624340
Value: Gas, convection
Create:
Burner #3624341
Value: Gas
Create:
Number of circuits #3624342
Value: Double-circuit
Create:
Thermal power #3624343
Value: 8.20 - 24 kW
Create:
Thermal load #3624344
Value: 9.10 - 25.80 kW
Create:
The combustion chamber #3624345
Value: Closed
Create:
Heated area #3624346
Value: 240 sq.m
Create:
Efficiency #3624347
Value: 93 %
Create:
Control #3624348
Value: Electronic
Create:
Installation #3624349
Value: Wall-mounted
Create:
Primary heat exchanger material #3624350
Value: Copper
Create:
Secondary heat exchanger material #3624351
Value: Steel
Create:
Mains voltage #3624352
Value: Single-phase
Create:
Expansion tank volume #3624353
Value: 6 l
Create:
Fuel #3624354
Value: Natural gas, liquefied gas
Create:
Natural gas consumption #3624355
Value: 2.73 cu. m/hour
Create:
LPG consumption #3624356
Value: 2 kg/hour
Create:
Nominal pressure of natural gas #3624357
Value: 13 - 25 mbar
Create:
Permissible LPG pressure #3624358
Value: 37 mbar
Create:
Heat carrier temperature #3624359
Value: 35 - 85 °С
Create:
Temperature in the DHW circuit #3624360
Value: 30 - 60 °С
Create:
Hot water capacity at t 25°C #3624361
Value: 13.7 l/min
Create:
Hot water capacity at t 30°C #3624362
Value: 11.3 l/min
Create:
Max. water pressure in the DHW circuit #3624363
Value: 10 bar
Create:
Max. water pressure in the heating circuit #3624364
Value: 3 bar
Create:
Gas connection #3624365
Value: 3/4"
Create:
Heating circuit connection #3624366
Value: 3/4"
Create:
Branch pipe for connecting the DHW circuit #3624367
Value: 1/2"
Create:
Coaxial chimney diameter #3624368
Value: 60/100 mm
Create:
Connection of a separate chimney diameter 80 mm #3624369
Value: Yes
Create:
Dimensions WxHxD #3624370
Value: 400x720x340 mm
Create:
Weight #3624371
Value: 29 kg
Create:
Image #6361994
URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id7906501945644043263.jpeg/orig
Create:
Preview image #6361995
URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id7906501945644043263.jpeg/orig
Donny Darko 30 April 2023 09:21:01
Name: Alpenhoff Gamburg 24T; Catalog: Heating boilers