Change history for item: Alpenhoff Hamburg 10T 10 kW dual circuit

  1. Donny Darko 09 July 2023 16:17:24
    1. Create: Description #3624207
      Value: Type of heating boiler: gas, max. thermal power: 10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3624208
      Value: Gas, convection
    3. Create: Burner #3624209
      Value: Gas
    4. Create: Number of circuits #3624210
      Value: Double-circuit
    5. Create: Thermal power #3624211
      Value: 8.20 - 10 kW
    6. Create: Thermal load #3624212
      Value: 9.10 - 14 kW
    7. Create: The combustion chamber #3624213
      Value: Closed
    8. Create: Heated area #3624214
      Value: 100 sq.m
    9. Create: Efficiency #3624215
      Value: 93 %
    10. Create: Control #3624216
      Value: Electronic
    11. Create: Installation #3624217
      Value: Wall-mounted
    12. Create: Primary heat exchanger material #3624218
      Value: Copper
    13. Create: Secondary heat exchanger material #3624219
      Value: Steel
    14. Create: Mains voltage #3624220
      Value: Single-phase
    15. Create: Expansion tank volume #3624221
      Value: 6 l
    16. Create: Fuel #3624222
      Value: Natural gas, liquefied gas
    17. Create: Natural gas consumption #3624223
      Value: 1.48 cu. m/hour
    18. Create: LPG consumption #3624224
      Value: 1.1 kg/hour
    19. Create: Nominal pressure of natural gas #3624225
      Value: 13 - 25 mbar
    20. Create: Permissible LPG pressure #3624226
      Value: 37 mbar
    21. Create: Heat carrier temperature #3624227
      Value: 35 - 85 °С
    22. Create: Temperature in the DHW circuit #3624228
      Value: 30 - 60 °С
    23. Create: Hot water capacity at t 25°C #3624229
      Value: 13.7 l/min
    24. Create: Hot water capacity at t 30°C #3624230
      Value: 11.3 l/min
    25. Create: Max. water pressure in the DHW circuit #3624231
      Value: 10 bar
    26. Create: Max. water pressure in the heating circuit #3624232
      Value: 3 bar
    27. Create: Gas connection #3624233
      Value: 3/4"
    28. Create: Heating circuit connection #3624234
      Value: 3/4"
    29. Create: Branch pipe for connecting the DHW circuit #3624235
      Value: 1/2"
    30. Create: Coaxial chimney diameter #3624236
      Value: 60/100 mm
    31. Create: Connection of a separate chimney diameter 80 mm #3624237
      Value: Yes
    32. Create: Dimensions WxHxD #3624238
      Value: 400x720x340 mm
    33. Create: Weight #3624239
      Value: 29 kg
    34. Create: Image #6361986
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id7906501945644043263.jpeg/orig
    35. Create: Preview image #6361987
      URL: https://avatars.mds.yandex.net/get-mpic/1603927/img_id7906501945644043263.jpeg/orig
  2. Donny Darko 30 April 2023 09:21:00
    Name: Alpenhoff Hamburg 10T 10 kW dual circuit; Catalog: Heating boilers