Change history for item: Mizudo M32TB 29.1 kW dual circuit

  1. Donny Darko 09 July 2023 16:10:15
    1. Create: Description #3622921
      Value: Type of heating boiler: gas, max. heating power: 29.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3622922
      Value: Gas, convection
    3. Create: Burner #3622923
      Value: Gas
    4. Create: Number of circuits #3622924
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3622925
      Value: 11.20 - 29.10 kW
    6. Create: Thermal load #3622926
      Value: 13 - 32 kW
    7. Create: The combustion chamber #3622927
      Value: Closed
    8. Create: Efficiency #3622928
      Value: 90.5 %
    9. Create: Control #3622929
      Value: Electronic
    10. Create: Installation #3622930
      Value: Wall-mounted
    11. Create: Mains voltage #3622931
      Value: Single-phase
    12. Create: Peculiarities #3622932
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3622933
      Value: 8 l
    14. Create: Equipment #3622934
      Value: Display
    15. Create: Fuel #3622935
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3622936
      Value: 3.19 cu. m/hour
    17. Create: Nominal pressure of natural gas #3622937
      Value: 7 - 25 mbar
    18. Create: Heat carrier temperature #3622938
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3622939
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3622940
      Value: 16.6 l/min
    21. Create: Hot water capacity at t 30°C #3622941
      Value: 13.1 l/min
    22. Create: Hot water capacity at t 35°C #3622942
      Value: 11.6 l/min
    23. Create: Max. water pressure in the DHW circuit #3622943
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3622944
      Value: 3 bar
    25. Create: Gas connection #3622945
      Value: 3/4"
    26. Create: Heating circuit connection #3622946
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3622947
      Value: 1/2"
    28. Create: Connection of a separate chimney diameter 80 mm #3622948
      Value: Yes
    29. Create: Dimensions WxHxD #3622949
      Value: 403x730x327 mm
    30. Create: Weight #3622950
      Value: 43 kg
    31. Create: Image #6361849
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id6914908243779994799.jpeg/orig
    32. Create: Image #6361850
      URL: https://avatars.mds.yandex.net/get-mpic/3721790/img_id2609760214486272705.jpeg/orig
    33. Create: Preview image #6361851
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id6914908243779994799.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:45
    Name: Mizudo M32TB 29.1 kW dual circuit; Catalog: Heating boilers