Change history for item: Mizudo M28TB 26.1 kW dual circuit

  1. Donny Darko 09 July 2023 16:09:28
    1. Create: Description #3622801
      Value: Type of heating boiler: gas, max. heating power: 26.10 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase,
    2. Create: Type of heating boiler #3622802
      Value: Gas, convection
    3. Create: Burner #3622803
      Value: Gas
    4. Create: Number of circuits #3622804
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3622805
      Value: 9.70 - 26.10 kW
    6. Create: Thermal load #3622806
      Value: 11.50 - 28 kW
    7. Create: The combustion chamber #3622807
      Value: Closed
    8. Create: Efficiency #3622808
      Value: 90.5 %
    9. Create: Control #3622809
      Value: Electronic
    10. Create: Installation #3622810
      Value: Wall-mounted
    11. Create: Mains voltage #3622811
      Value: Single-phase
    12. Create: Peculiarities #3622812
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3622813
      Value: 6 l
    14. Create: Equipment #3622814
      Value: Display
    15. Create: Fuel #3622815
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3622816
      Value: 2.72 cu. m/hour
    17. Create: Nominal pressure of natural gas #3622817
      Value: 7 - 25 mbar
    18. Create: Heat carrier temperature #3622818
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3622819
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3622820
      Value: 14 l/min
    21. Create: Hot water capacity at t 30°C #3622821
      Value: 11.8 l/min
    22. Create: Hot water capacity at t 35°C #3622822
      Value: 10 l/min
    23. Create: Max. water pressure in the DHW circuit #3622823
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3622824
      Value: 3 bar
    25. Create: Gas connection #3622825
      Value: 3/4"
    26. Create: Heating circuit connection #3622826
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3622827
      Value: 1/2"
    28. Create: Connection of a separate chimney diameter 80 mm #3622828
      Value: Yes
    29. Create: Dimensions WxHxD #3622829
      Value: 403x730x327 mm
    30. Create: Weight #3622830
      Value: 42 kg
    31. Create: Image #6361807
      URL: https://avatars.mds.yandex.net/get-mpic/4449143/img_id1661659076304870198.jpeg/orig
    32. Create: Image #6361808
      URL: https://avatars.mds.yandex.net/get-mpic/4947485/img_id6822575812655607486.jpeg/orig
    33. Create: Preview image #6361809
      URL: https://avatars.mds.yandex.net/get-mpic/4449143/img_id1661659076304870198.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:44
    Name: Mizudo M28TB 26.1 kW dual circuit; Catalog: Heating boilers