Change history for item: Mizudo M24TB

  1. Donny Darko 09 July 2023 16:09:16
    1. Create: Description #3622741
      Value: Type of heating boiler: gas, max. thermal power: 24 kW, number of circuits: double-circuit, placement: wall-mounted, fuel: natural gas, liquefied gas, type of combustion chamber: closed, type of power supply: single-phase, at
    2. Create: Type of heating boiler #3622742
      Value: Gas, convection
    3. Create: Burner #3622743
      Value: Gas
    4. Create: Number of circuits #3622744
      Value: Double-circuit, bithermic heat exchanger
    5. Create: Thermal power #3622745
      Value: 8.20 - 24 kW
    6. Create: Thermal load #3622746
      Value: 9.60 - 24 kW
    7. Create: The combustion chamber #3622747
      Value: Closed
    8. Create: Efficiency #3622748
      Value: 90.5 %
    9. Create: Control #3622749
      Value: Electronic
    10. Create: Installation #3622750
      Value: Wall-mounted
    11. Create: Mains voltage #3622751
      Value: Single-phase
    12. Create: Peculiarities #3622752
      Value: Air vent, built-in expansion tank, built-in circulation pump, pressure gauge, safety valve, connector for external control, thermometer
    13. Create: Expansion tank volume #3622753
      Value: 6 l
    14. Create: Equipment #3622754
      Value: Display
    15. Create: Fuel #3622755
      Value: Natural gas, liquefied gas
    16. Create: Natural gas consumption #3622756
      Value: 2.33 cu. m/hour
    17. Create: Nominal pressure of natural gas #3622757
      Value: 7 - 25 mbar
    18. Create: Heat carrier temperature #3622758
      Value: 30 - 80 °С
    19. Create: Temperature in the DHW circuit #3622759
      Value: 35 - 60 °С
    20. Create: Hot water capacity at t 25°C #3622760
      Value: 12.3 l/min
    21. Create: Hot water capacity at t 30°C #3622761
      Value: 10 l/min
    22. Create: Hot water capacity at t 35°C #3622762
      Value: 8.8 l/min
    23. Create: Max. water pressure in the DHW circuit #3622763
      Value: 8 bar
    24. Create: Max. water pressure in the heating circuit #3622764
      Value: 3 bar
    25. Create: Gas connection #3622765
      Value: 3/4"
    26. Create: Heating circuit connection #3622766
      Value: 3/4"
    27. Create: Branch pipe for connecting the DHW circuit #3622767
      Value: 1/2"
    28. Create: Connection of a separate chimney diameter 80 mm #3622768
      Value: Yes
    29. Create: Dimensions WxHxD #3622769
      Value: 403x693x247mm
    30. Create: Weight #3622770
      Value: 29 kg
    31. Create: Image #6361800
      URL: https://avatars.mds.yandex.net/get-mpic/4367383/img_id9186798363654315519.jpeg/orig
    32. Create: Image #6361801
      URL: https://avatars.mds.yandex.net/get-mpic/4453979/img_id6233652762555237382.jpeg/orig
    33. Create: Preview image #6361802
      URL: https://avatars.mds.yandex.net/get-mpic/4367383/img_id9186798363654315519.jpeg/orig
  2. Donny Darko 30 April 2023 09:20:44
    Name: Mizudo M24TB; Catalog: Heating boilers